User's Manual

SYSTEM DESCRIPTION AND INSTALLATION MANUAL
T
3
CAS/Part No.9005000
Table 4-1: T
3
CAS Computer Unit Interface Description (cont)
(Applicable to Part No. 9005000-10000, -10101, -10202, -10204, and -11203)
Connector
Pin
Designation
Functional Description
RTP-12H
+28 V dc Discrete Input
Spare
RTP-12J
Discrete Input (Gnd/Open), Latch
Air Data Source Select
RTP-12K
Discrete Input (Gnd/Open)
Control Panel Source Select
RTP-13A
Discrete Input (Gnd/Open), Latch
Extended Squitter Disable
RTP-13B
Programmable/Strobed Ground Discrete Output
GPWS Caution /TAWS/XPDR Lamp 500 mA
RTP-13C
Programmable/Strobed Ground Discrete Output
Spare Output /TAWS/XPDR 500 mA
RTP-13D
Programmable/Strobed Ground Discrete Output
GPWS Warning /TAWS/XPDR Lamp 500 mA
RTP-13E
Programmable/Strobed Ground Discrete Output
Spare /TAWS/XPDR 500 mA
RTP-13F
Programmable/Strobed Ground Discrete Output
Spare /TAWS/XPDR 500 mA
RTP-13G
Programmable/Strobed Ground Discrete Output
Spare /TAWS/XPDR 500 mA
RTP-13H
Programmable/Strobed Ground Discrete Output
Spare /TAWS/XPDR 500 mA
RTP-13J
Ground Discrete Output
Terrain Display Select #1 500 mA
RTP-13K
Programmable/Strobed Ground Discrete Output
Spare /TAWS/XPDR 500 mA
RTP-14A
Ground Discrete Output
Terrain Display Select #2 500 mA
RTP-14B
Ground Discrete Monitor Output
GPWS Monitor 250 mA
RTP-14C
Ground Discrete Monitor Output
Terrain Not Available Monitor 250 mA
RTP-14D
Ground Discrete Monitor Output
Terrain Monitor 250 mA
RTP-14E
Discrete Input (Gnd/Open)
XPDR Functional Test
Pub. No. 8600200-001, Revision 004
34-45-29
4-9
04 Nov 2014
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.