access control TECHNOLOGY Operating & Installation Instructions for ACTSmart 2 Product Range
ACTSmart2 Operating and Installation Manual Rev. 1.1 Contents Installation Notes............................................................. ......................................................................4 Product Specification ....................................................... ......................................................................4 30 Second Programming Guide (1080) ................................... ..............................................................
ACTSmart2 Operating and Installation Manual Rev. 1.1 Installation Notes • Remember to Factory Default the ACTSmart before programming • Remember to place the supplied varistor across the terminals of the door strike coil to protect the relay contacts • Don’t mount the ACTSmart Prox units near RF sources (Eg mobile phones, radio transmitters, computer monitors) or metal surfaces. • Remember that the ACTSmart PIN and Prox units default to Card operation. Card and PIN operation must be programmed in.
ACTSmart2 Operating and Installation Manual Rev. 1.1 30 Second Programming Guide ACTSmart2 Pin & Prox (1080) (For typical Standalone System) 1. Enter Programming Mode. Press ✘ button followed by the programming code (default is 9999) The LED will flash amber. 2. Add a Batch of Cards Press 10, then present the first card in the batch followed by the last card in the batch. Press ✔ button to complete. 3. Add a PIN Code Press 12, and then enter a 4-digit PIN code. Press ✔ button to complete.
ACTSmart2 Operating and Installation Manual Rev. 1.1 30 Second Programming Guide ACTSmart2 PIN Only (1090) 1. Enter Programming Mode. Press ✘ button followed by the programming code (default is 9999) The LED will flash amber. 2. Add a PIN Code Press 12, and then enter a 4-digit PIN code. Press ✔ button to complete. 3. Set Desired Door Relay Active Time Press 20, and then enter the desired number of seconds from 000-255 (three digits with leading zeros). Press ✔ button to complete. 4.
ACTSmart2 Operating and Installation Manual Rev. 1.
ACTSmart2 Operating and Installation Manual Rev. 1.1 ACTSmart Operation The ACTSmart family consists of Proximity only, Pin and Proximity and PIN only units. Each ACTSmart can operate in standalone mode. Up to 8 ACTSmart devices can be connected on a RS485 network. The ACTSmart will support a maximum of 1000 tokens. A token may be a card, keyfob or a PIN code.
ACTSmart2 Operating and Installation Manual Rev. 1.1 Adding a Card Batch: Step 1 2 3 4 5 Keypad Entry Operation 10 Present Card Present Card Enter 1-8, (optional)* Press ✔ Add Card Batch First card in Batch (lowest number card) Last Card in Batch (highest number card) Select each door this batch enabled for End programming card batch Note: the buzzer will sound while cards are loaded into memory.
ACTSmart2 Operating and Installation Manual Rev. 1.1 Adding a Card Batch using the keypad: Step 1 2 Keypad Entry 16 Enter 10-digit card number 3 4 5 Enter 10-digit card number 1-8, (optional)* Press ✔ Operation Add Card Batch 10-digit First Card number with leading zeros. Eg. Card 54321 enter 0000054321. Second Card number Select each door to which these cards are enabled End Adding Card Batch — Note: the buzzer will sound while cards are loaded into memory.
ACTSmart2 Operating and Installation Manual Rev. 1.1 Change Programming Code: Step 1 2 Keypad Entry Operation 23 0001-9999 Change Programming code New 4 - 6 digit programming code Change Number of PIN Digits: Step 1 2 Keypad Entry Operation 24 4-6 Change Number of PIN digits Select number of PIN digits in range 4 to 6. When set, the codes require leading zeros Eg. Code 9999 becomes 009999 for 6 digits.
ACTSmart2 Operating and Installation Manual Rev. 1.1 User Arm Function: Users with this function may arm or disarm the door after a vaild card or PIN is presented. Remember the Arming Door option must be set on the Smart2 (Option 42). While the door is armed, the door is locked and access is denied to other users until the door is disarmed. The red LED flashes to indicate the door is armed. An auxilliary output may be switched to signal the state of the door.
ACTSmart2 Operating and Installation Manual Rev. 1.
ACTSmart2 Operating and Installation Manual Rev. 1.
ACTSmart2 Operating and Installation Manual I/O Function Codes Code 14 15 Rev. 1.1 (continued) Function Door Armed Operation This output toggles when a user with the armed function presents a valid card or PIN. This can be used to arm or disarm an alarm panel. The output may be set to pulse for 2 seconds instead of toggle. See Option 43. Panel Armed Input When this input is low, the door is locked and the red LED flashes. This input informs the ACTSmart2 that the panel is armed.
ACTSmart2 Operating and Installation Manual Rev. 1.1 Adding a PIN for Second Door: Step 1 Keypad Entry 71 Operation Add PINs 2 3 4 0001-9999 1-8, (optional)* Press ✔ 4 - 6 digit PIN code Select each door this PIN is valid for End programming PINs (Make sure Option 40 is set on PIN and Prox units.
ACTSmart2 Operating and Installation Manual Rev. 1.1 Programming a Network System Up to 8 ACTSmart devices can be connected on the network. See the ACTSmart Network Installation diagram to complete the necessary connections. Programming Door Numbers To allow some users through a door and prevent access to other users, each ACTSmart on the network must be given a door number (1-8). An ACTSmart Proximity Only Unit requires a door number if it is to be programmed with advanced options.
ACTSmart2 Operating and Installation Manual Rev. 1.1 Find Door Number: Step Keypad Entry 1 61 2 1-8 3 Press a key or present a card Operation Find Door Numbers Enter the door number to be found. The ACTSmart assigned the door number starts to beep. To stop the ACTSmart beeping.
ACTSmart2 Operating and Installation Manual Rev. 1.1 Programming ACTSmart Prox Only (1070) To program an ACTSmart Prox Only device, a Programming Card must be assigned to the ACTSmart. The Programming Card may be any proximity card. If you have received a batch of cards, use the first (lowest numbered) card in the batch as the Programming Card. To set the Programming Card into the ACTSmart Prox do the following: 1.
ACTSmart2 Operating and Installation Manual Rev. 1.1 Programming for SmartLock: Step 1 2 3 4 5 6 Present Programming Card Programming Card Programming Card Programming Card Programming Card Programming Card Operation Buzzer sounds intermittently and the LED flashes Input 1 = Door Contact, AUX I/O 1 = Door Alarm, AUX I/O 2 = SmartLock. See the SmartLock Connections diagram.
Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie ACTSmart Standalone Installation Diagram ACTSmart2 Operating and Installation Manual Rev. 1.
Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie ACTSmart Interlock Connections ACTSmart Fire Alarm Override Connections ACTSmart2 Operating and Installation Manual Rev. 1.
Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie ACTSmart Network Installation Diagram ACTSmart2 Operating and Installation Manual Rev. 1.
ACTSmart2 Operating and Installation Manual Rev. 1.1 SmartLock Connection Diagram Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.
Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie ACTSmart Alarm Panel Wiring Diagram ACTSmart2 Operating and Installation Manual Rev. 1.
Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie ACTPro Connections Diagram ACTSmart2 Operating and Installation Manual Rev. 1.
Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie 2 Door Wiring Diagram ACTSmart2 Operating and Installation Manual Rev. 1.
Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie ACTSmart System Diagram ACTSmart2 Operating and Installation Manual Rev. 1.
Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie ACTSmart Mounting Instructions for Flush-Mount Unit ACTSmart2 Operating and Installation Manual Rev. 1.
Access Control Technology, Unit 8, Tallaght Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Web: http://www.accesscontrol.ie E-mail: sales@accesscontrol.ie ACTSmart Mounting Instructions for Surface Mount Unit ACTSmart2 Operating and Installation Manual Rev. 1.
Smart access control TECHNOLOGY User List User Name Card Number PIN Doors 1 2 3 4 5 6 7 8 Access Control Technology, Unit 8, IDA Business Park, Whitestown, Dublin 24, Ireland. TEL:353-1-4622585 FAX: 353-1-4622587 WEB: http://www.accesscontrol.ie E-MAIL: sales@ accesscontrol.