User`s manual

49
OFF
When the TITLE DISPLAY is set <OFF>, no title will be displayed on the
screen even titles are set in advance.
B-3-11 TITLE SETTING
Up to 16 zone titles can be set with maximum 20 characters for each title; two
mask zones are allowed to set in a view area. Users can name the zone titles with
privacy mask ID numbers for future recognition.
Follow the steps to set a camera title.
(1) Operate speed dome to certain view area where you want to set a title for it.
(2) Turn on OSD and select <TITLE SETTING>.
(3) Select a number to indicate the view area.
(4) Press <ENTER> to go into editing mode.
TITLE SETTING: 01
0 1 2 3 4 5 6 7 8 9 EXIT
A B C D E F G H I J SAVE
K L M N O P Q R S T LEFT
U V W X Y Z : / . , RIGHT
[ ] + ? - DELETE
TITLE:
ABC
(5) Choose a character with direction keys and then press <ENTER> to input.
Example: <A> <ENTER>, <B> <ENTER>, <C> <ENTER>
TITLE: ABC
(6) To delete entered characters, move the cursor to <LEFT> or <RIGHT> and
press <ENTER> to select a character in entry field, then move the cursor to
<DELETE> and press <ENTER> to delete the selected character.
(7) When the setting is completed, move the cursor to <SAVE> and press
<ENTER> to save.
B-3-12 ALARM SETTING
The integrated high speed dome provides eight alarm inputs and two alarm
outputs (N.O. and N.C.) to connect alarm devices. With this function, dome will
cooperates with alarm system to catch the event images. For wiring, please refer
to the installation guide and/or qualified service personnel. Alarm parameters can