Bullet Camera Series Hardware Manual D41, D42, E41, E42, E43 E41A, E42A, E43A Ver.
Hardware Manual Table of Contents Precautions 4 Safety Instructions ........................................................................... 6 Introduction 7 List of Models.................................................................................... 7 Package Contents............................................................................. 8 Physical Description ........................................................................ 9 Installation Procedures 10 Mount the Camera .....
Hardware Manual Attach the Sunshield ...................................................................... 33 Appendix 34 How to Make an Ethernet Cable .................................................... 34 3 www.acti.
Hardware Manual Precautions Read these instructions You should read all the safety and operating instructions before using this product. Heed all warnings You must adhere to all the warnings on the product and in the instruction manual. Failure to follow the safety instruction given may directly endanger people, cause damage to the system or to other equipment.
Hardware Manual Federal Communications Commission Statement This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Hardware Manual Safety Instructions Don’t open the housing of the product Cleaning Disconnect this video product from the power supply before cleaning. Attachments Do not use attachments not recommended by the video product manufacturer as they may cause hazards. Water and Moisture Do not use this video product near water, for example, near a bathtub, washbowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool and the like.
Hardware Manual Introduction List of Models This hardware manual contains the following models: D41 1MP Bullet with D/N, IR, Vari-focal lens D42 3MP Bullet with D/N, IR, Vari-focal lens E41 1MP Bullet with D/N, IR, Basic WDR, Vari-focal lens E41A 1MP Bullet with D/N, IR\, Basic WDR, Vari-focal lens E42 3MP Bullet with D/N, IR, Basic WDR, Vari-focal lens E42A 3MP Bullet with D/N, IR, Basic WDR, Vari-focal lens E43 5MP Bullet with D/N, IR, Basic WDR, Vari-focal lens E43A 5MP Bullet with D/N,
Hardware Manual Package Contents Bullet Camera Sunshield Conduit Gland Mounting Screw Kit Sunshield Screw Kit Quick Installation Guide Bracket Bracket Plate Warranty Card 8 www.acti.
Hardware Manual Physical Description 1) Reset Button Use the Reset Button to reset the camera to its factory default settings. While the camera is powered on, press and hold the Reset button for 5 seconds or until the Power LED lights up. 2) Power LED The Power LED lights up when the camera is connected to the power source and the camera starts the boot up process. Then, the Power LED goes off when the boot process is complete.
Hardware Manual Installation Procedures Mount the Camera Using the Bundled Bracket 1. Mark the location of the three (3) screw holes using the bracket plate included in the package. NOTE: Depending on the surface where you will install the camera, it may be necessary to drill the holes and use the supplied screw tox. 2. Attach the plate to the surface using the three (3) supplied screws. 3. Attach the bracket to the plate. 10 www.acti.
Hardware Manual 4. Depending on how you want to install the camera, attach the camera to the bracket through one of the two (2) holes below: If the camera will be installed indoors and the use of sunshield is not necessary, you may also use one of the two (2) holes on top of the camera to mount the bracket to the ceiling. First, remove the pre-installed screw nut using a wrench (not included in the package). 5. Adjust the camera viewing angle and tighten the knob to fix the camera position.
Hardware Manual 6. Connect an Ethernet cable from the network side to the Ethernet port of the camera to complete the installation. See Basic Connections on page 23 for more information. Camera Side Network Side NOTES on using Ethernet cables: For outdoor installations, it is recommended to use exterior-grade Ethernet cables (CAT5/CAT5e/CAT6); ordinary Ethernet cables are only designed for indoor use and may deteriorate quickly when exposed to outdoor elements.
Hardware Manual Other Mounting Options In areas with fierce weather conditions, the light bundled bracket can be replaced by a heavy duty outdoor bracket combined with additional mounting accessories. Below are the optional mounting accessories that you can use with the camera. Mount Types Accessories Corner Mount Suitable when mounting the camera on a corner wall. PMAX-1103 PMAX-0402 + Pole Mount Suitable when mounting the camera on a pole.
Hardware Manual Waterproof Cable Installation The camera and the pre-installed network cable are resistant to salt water, weak acid, alcohol, oil, grease and other common solvents. However, in areas with fierce weather conditions and those that can easily be flooded, ensure that the exposed length of cable is also protected. It is recommended to use a flexible conduit with 1/2” diameter and the conduit gland (included in the package) to protect the camera cabling.
Hardware Manual Step 1: Remove the Pre-installed Network Cable (“Pigtail”) 1. Loosen the three (3) screws to detach the back cover. NOTE: A cable is connected inside the camera; do not abruptly pull the back cover. 2. Disconnect the network connector. 3. Remove the pre-installed cable gland and network cable using a wrench (not included in the package). 15 www.acti.
Hardware Manual Step 2: Prepare the Conduit Gland and Flex Conduit 1. Disassemble the bundled conduit gland as shown below. Body Clamping Nut Sealing Insert Lock Nut 2. Pull the Ethernet cable through the flex conduit. 3. Insert the clamping nut through the flex conduit. 16 www.acti.
Hardware Manual 4. Insert the sealing insert and attach it at the end of the flex conduit. Step 3: Install the Ethernet Cable 1. Insert the body (A) to the back cover and secure it with the lock nut (B). (B) (A) 2. Insert the Ethernet cable through the back cover and then align the sealing insert to the gland body. 17 www.acti.
Hardware Manual 3. Secure the clamping nut to the body. Step 4: Connect the Ethernet Cable 1. Connect the Ethernet cable to the Ethernet port inside the camera. 2. When done, close the back cover by tightening the three (3) screws. 18 www.acti.
Hardware Manual Replace the Pre-Installed Network Cable The pre-installed network cable comes with an Ethernet port (female connector), or known as a “pigtail”. The length of the cable is around 14 ~ 35 cm (varies by model). The network cable and gland are resistant to salt water, weak acid, alcohol, oil, grease and common solvents. 14 cm ~ 35 cm In case the installation environment requires a change of this network cable, follow the step-by-step procedures in this section to do so.
Hardware Manual Step 1: Remove the Pre-installed Network Cable (“Pigtail”) 1. Loosen the three (3) screws to detach the back cover. NOTE: A cable is connected inside the camera; do not abruptly pull the back cover. 2. Disconnect the network connector (A) and remove the sealing nut (B). (A) (B) 3. Pull out the network cable from the back cover and disassemble the parts as marked below. Seal Claw Sealing Nut 4.
Hardware Manual Step 2: Install the New Ethernet Cable 1. Insert the new Ethernet cable through the sealing nut, claw, seal, and cable gland of the back cover. 2. Attach the RJ-45 connector to the Ethernet cable. See How to Make an Ethernet Cable on page 34 for more information. 3. Assemble the seal and claw, and then connect the RJ-45 connector to the Ethernet port inside the camera. 2 2 1 2 4. Attach the back cover by tightening the three (3) screws. 21 www.acti.
Hardware Manual 5. Tighten the sealing nut. NOTES on using Ethernet cables: When replacing the pre-installed network cable, it is recommended to use exterior-grade Ethernet cables (CAT5/CAT5e/CAT6); ordinary Ethernet cables are only designed for indoor use and may deteriorate quickly when exposed to outdoor elements. Exterior-grade Ethernet cables are waterproof and do not require a conduit. 22 www.acti.
Hardware Manual Basic Connections To connect the camera, you need to prepare the following: Power over Ethernet (PoE) supported switch (to connect multiple cameras) or PoE injector (to connect a single camera) Ethernet cables Connecting a Single Camera To connect a single camera, use a PoE injector to supply both data and power to the camera using one Ethernet cable. Follow the procedures below: 1. Connect the camera to the PoE injector using an Ethernet cable. 2.
Hardware Manual Connecting Multiple Cameras To connect multiple cameras, use a PoE switch. 1. Connect the camera(s) to the PoE switch using Ethernet cables. 2. Connect the PoE switch to a network and an AC power source. 3. Connect a PC to the same network. Network Ethernet Cable Ethernet Cable (Data) PoE Switch Power Cable Ethernet Cables (Data+Power) AC Power Source Cameras 4.
Hardware Manual Accessing the Camera Configure the IP Addresses In order to be able to communicate with the camera from your PC, both the camera and the PC have to be within the same network segment. In most cases, it means that they both should have very similar IP addresses, where only the last number of the IP address is different from each other. There are 2 different approaches to IP Address management in Local Area Networks – by DHCP Server or Manually.
Hardware Manual launch the default browser of the PC with the IP address of the target camera filled in the address bar of the browser already. If you work with our cameras regularly, then there is even a better way to discover the cameras in the network – by using IP Utility.
Hardware Manual Using the Default Camera IP Address If there is no DHCP server in the given network, the user may have to assign the IP addresses to both PC and camera manually to make sure they are in the same network segment. When the camera is plugged into network and it does not detect any DHCP services, it will automatically assign itself a default IP: 192.168.0.100 Whereas the default port number would be 80.
Hardware Manual Manually adjust the IP addresses of multiple cameras: If there are more than 1 camera to be used in the same local area network and there is no DHCP server to assign unique IP addresses to each of them, all of the cameras would then have the initial IP address of 192.168.0.100, which is not a proper situation for network devices – all the IP addresses have to be different from each other.
Hardware Manual Access the Camera Now that the camera and the PC are both having their unique IP addresses and are under the same network segment, it is possible to use the Web browser of the PC to access the camera. You can use any of the browsers to access the camera, however, the full functionality is provided only for Microsoft Internet Explorer.
Hardware Manual The following examples in this manual are based on Internet Explorer browser in order to cover all functions of the camera. Assuming that the camera’s IP address is 192.168.0.100, you can access it by opening the Web browser and typing the following address into Web browser’s address bar: http://192.168.0.100 Upon successful connection to the camera, the user interface called Web Configurator would appear together with the login page.
Hardware Manual To check the firmware version through the Web Configurator, access the Setup page and click System > System Info. 1 2 3 For further operations, please refer to the Firmware User Manual. 31 www.acti.
Hardware Manual Other Adjustments and Accessories Adjust the Viewing Angle 1. Open the front cover. 2. Based on the live view from the camera, adjust the focal length and focus of the target area. Focal Length Focus 3. When done, close the front cover. CAUTION: The front cover must be tightly closed to ensure water or dust does not go through any opening. 32 www.acti.
Hardware Manual Attach the Sunshield The use of sunshield is optional if the camera will be installed indoors. However, if the camera will be installed outdoors, attach the sunshield to protect the lens from all types of weather and lighting conditions. 1. Loosely secure the supplied screws and washers to attach the sunshield. 2. Slide to adjust the sunshield to cover the lens as far as possible but out of the camera’s live view. 3. Tighten the screws to fix the position of the sunshield. 33 www.acti.
Hardware Manual Appendix How to Make an Ethernet Cable 1. Prepare the following tools: Ethernet cable without connectors RJ-45 Connector (x2) RJ45 Crimping Tool Scissors 2. Cut about 1 inch into the plastic sheath from the end of the cable. 1 inch 3. Unwind the wires and arrange them according to the color sequence below. 1) 2) 3) 4) 5) 6) 7) 8) Stripe Orange Orange Stripe Green Blue Stripe Blue Green Stripe Brown Brown 4. Pinch the wires between your fingers and straighten them out.