Technical data

5
Parameterizing motor data
ID 442281.00
WE KEEP THINGS MOVING
Operating Manual
32
5.3 Further motor datas
5.3.1 Current controller
Parameters B64 to B68 pertain to the setting of the current controller. If an initial
test with the default settings of the parameters does not provide the desired re-
sults, we recommend using the current controller optimization. It is performed with
the action B42 Optimize current controller. Afterwards, save the measured values
with A00 Save values.
5.3.2 Thermal model
The parameters B70, B71 and B72 describe a motor model for the protection of
the motor. The default values are usually sufficient.
5.3.3 Absolute Limit values
The parameters B82 I-max and B83 n-max motor are limit values which may nev-
er be exceeded.
Information
Since parameters in the parameter lists and assistant are indicated or
hidden based on how B20 is set, all parameters are not always visible
for each setting.