Technical data
10
Parameterizing in-/outputs
ID 442281.00
WE KEEP THINGS MOVING
Operating Manual
42
All available parameters can
be entered in the source pa-
rameters.
To be able to poll application status signals, the signals must be allocated to an
output (BA, AA, parameter). There is a source parameter for each output in which
the signals available for the particular application can be selected / inscribed.
Source parameters F61 and F62 are used for the binary outputs BA1 and BA2
shown in the diagram. At the same time, the signal is written in a parameter (D200
bit 1 here). This parameter can be read from a fieldbus system.
The indicator parameter (D181 in the diagram) shows the signal state after han-
dling by the application. It is used to check the signal path. The application de-
scriptions specifies for each signal the possible outputs and the related selection
parameters as well as the fieldbus and indicator parameter.