Technical data

Service
Operating Manual
ID 442281.00
WE KEEP THINGS MOVING
55
12
If the download failed, check the following points:
1. After you pressed the button Download per Software start..., the following in-
struction appears after a certain amount of time:
Switch off and on again the control section of the connected inverter ....
Switch the power supply on X11 off and on again to continue with the down-
load. Then proceed with step 12.
The mot. files are stored on your PC during the installation of POSITool. The
name of the mot. file for the FDS 5000 begins with f.
12.5 Actions
Actions are functions which are executed by the inverter automatically after their
start.
Actions are controlled and analyzed using special parameters. The parameters
contain three elements.
You can start the action via the element 0 (e.g. A00.0) The element 1 (e.g. A00.1)
shows you the action's progress. Element 2 (e.g. A00.2) shows the result. You
can start an action via every interface (operator panel on the inverter, fieldbus or
POSITool in online mode).
For some actions, power must be applied to the motor and the motor must be free
to turn. For this reason the inverter must be enabled if you want to run these ac-
tions. Other actions can be performed without energizing the motor. Since these
two action groups are executed differently, they will be described separately be-
low.
12.5.1 Actions without enable
Actions which do not need an enable before they can be executed are:
A00 Save values
A37 Reset memorized values
Proceed as shown below:
12 Wait until a dialog message reports that the firmware was saved to the invert-
er.
Ö You have performed the firmware download.
Executing actions without enable
1 Set element 0 of 0 to the value 1 (e.g., A00.0 = 1).
Ö Element 1 indicates the progress of the action (e.g., A00.1 = 33 %).
2 Wait until element 0 indicates the value 0 again (e.g., A00.0 = 0)
Ö Element 2 indicates the results of the action (e.g., A00.2 = 0:error free).