29:AX5000/IncEnc A faulty POSISwitch AX 5000 op-
tion at X4 or a wire break in the A-
track for an incremental encoder
was detected.
Replace the AX 5000 option.
Check the encoder cable of the incremental encoder.
programmed ac-
knowledgement
30:Opt2 incomp Option 2 is not the latest version. Install the latest version of the option board. programmed ac-
knowledgement
31:X140EnDatAlar The EnDat® encoder at X140 re-
ports an alarm.
Switch the inverter off and back on again.
The encoder is faulty. Please contact our service de-
partment, see section 1.4 Further support
programmed ac-
knowledgement
32:X140EnDatCRC Errors accumulate during data
transfer. The encoder is is not
available.
Make sure that the correct encoder type is connect-
ed.
Check the connection and shielding of the encoder
cable.
Reduce the electromagnetic interference.
Please contact our service department, see section
1.4 Further support
programmed ac-
knowledgement
33:IGB-speed G297 exceeded on the IGB Check the parameterization of G297.
Check the producer.
Please contact our service department, see section
1.4 Further support
programmed ac-
knowledgement
34:battery low When switching on the inverter, it
was determined that the voltage
of the battery has fallen below the
warning limit of the encoder. Ref-
erencing of the axis remains in-
tact. However, the remaining
service life of the backup battery
is limited.
Replace the AES battery before the next time the in-
verter is switched off. Note also the Absolute Encod-
er Support AES operating instructions (see section
1.3 Other manuals).
programmed ac-
knowledgement
Cause Description Measure Acknowledge-