User`s manual

www.acti.com
Firmware Users Manual V5.05.07
73
region from Runtime profile to Event profile. The profile will return to runtime settings at the end of
this event. You may program one motion detection region to be disabled at runtime, but enable it
with event handler under some circumstances.
Send URL command: Select the URL command to include in the response set. Two different
commands will be sent at the time when the event is triggered and untriggered.
Change to Night Mode (Selected models only): For some models, you may force the Camera
into Night mode. The camera will return to its previous setting (whether auto or forced day/ night)
upon the end of the event.
Go to a preset point: if the device is a PTZ camera, and the Go to Preset point Event
Configuration is setup, then you may include this in the response section of the event rule. The
camera will return to the position right before the event starts when the event is untriggered.
Be sure to do Save and Reboot after youve updated the event settings. Only then will the
settings be commited to physical memory. You may lose the settings to power loss or
other situations if you do not do this step.
Manual Event
You may select one event in the Manual Event area below the event list to be triggered via web
UI.
Once selected, the trigger button on the video display screen will show as clickable. Click to
trigger the selected event. This is useful during event rule testing.