SDS

Page 7 of 12
Report No.: 18PNS090101 01001
GUANGDONG UTL CO., LTD.
Lianding Testing Building, No.18 Center Road of Yayuan Industrial Zone, Nancheng District, Dongguan,
Guangdong, China
Tel: +86-769-3893 3228 Fax: +86-769-3893 3229 E-mail: sales@gdutl.com
Control parameters
TLV(USA) 0.02mg/m³
MAK(Germany) 0.1mg/m³
Other Exposure Guidelines Vacated limits revoked by the Court of Appeals decision in AFL-CIO v.
OSHA, 965 F.2d 962 (11th Cir., 1992).
Appropriate engineering controls
Engineering Measures Showers
Eyewash stations
Ventilation systems
Use adequate general or local exhaust ventilation to keep airborne concentrations below the permissible
Exposure limits. Ensure or adequate ventilation.
Individual protection measures, such as personal protective equipment
Eye/Face Protection:
Tightly sealed goggles
Body protection:
Protective work clothing.
Skin protection:
Protective gloves
Material of gloves:
The selection of the suitable gloves does not noly depend on the material, but also on further marks of quality
and varies from manufacturer to manufacturer. As the product is preparation of several substances, the
resistance of the glove material can not to be calculated in advance and has therefore to be checked prior to
the application.
Penetration time of glove material:
The exact break trough time has to be found out by manufacturer of the Protective gloves and has to be
observed.
Respiratory Protection No protective equipment is needed under normal use conditions. If exposure limits are
exceeded or irritation is experienced, ventilation and evacuation may be required.
Hygiene Measures Handle in accordance with good Industrial hygiene and safety practice.
Ingredients with limit values that require monitoring at the workplace:
12190-79-3 Lithium Cobalt Oxide