IP Indoor High Speed Dome CAM-6500 series Ver.
0 0 1. 2. PRECAUTIONS Read these instructions All the safety and operating instructions should be read before the product is operated. Heed all warnings All warnings on the product and in the instruction manual should be adhered to. The symbol indicates the following items, please carefully read the description next to each symbol. a. Failure to follow the safety instruction given may directly endanger people, cause damage to the system or to other equipment. b.
typographical or technical errors and reserve the right to make changes to the product and manuals without prior notice. FCC/CE Regulation NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Table of Contents 0 PRECAUTIONS________________________________________________ 0-1 Copyright __________________________________________________________________ 0-1 Trademarks ________________________________________________________________ 0-1 Liability ___________________________________________________________________ 0-1 FCC/CE Regulation __________________________________________________________ 0-2 1 INTRODUCTION ________________________________________________1 1.
B-3: Configuration Menu_______________________________________________________42 B-3-1 DEFAULT CAMERA __________________________________________________43 B-3-2 BACKLIGHT ________________________________________________________43 B-3-3 FOCUS _____________________________________________________________44 B-3-4 APERTURE _________________________________________________________45 B-3-5 AE MODE ___________________________________________________________45 B-3-6 WBC MODE _____________________________
11 1.1 INTRODUCTION Package Contents CAM-6500 series Warranty Card Product CD Power & A/V Cable LAN/WAN Cable Power Adaptor (Option) 5.
1.2 Features and Benefits The IP High Speed Dome is designed to deliver superb performance and durability with an intelligent and stylish housing. It also provides a realiable real time images with outstanding image quality (D1, 720x480) at reasonable bandwidth through a standard TCP/IP network. That’s because it is Ethernet (LAN and WAN) ready and has a powerful ARM9 SoC and the MPEG-4 compression ASIC inside.
MODEL) z Low-Light Application Digital Slow Shutter and Electronic Shutter functions are provided for clear and high quality image. The minimum illumination is 0.01 Lux. z Perfect Contrast Solution for High Image Quality Wide Dynamic Range function is a salient features incorporated to fit your needs (23x MODEL) z Privacy Mask for Privacy Protection There is up to 24 privacy zones of camera view programmable. This is specially designed to avoid any intrusive monitoring at specific region.
The IP high speed dome provides two RJ-45 connectors. One is WAN and the other is LAN. The WAN port connects to the internet and LAN port connects to the local network. Since the internet’s bandwidth is very critical, the WAN port is equipped with a low latency PPPoE (Point-to-Point over Ethernet) which has excellent transmission speed and enables the IP high speed dome to connect to an ADSL or a cable modem.
1.3 Safety Instructions z Don’t use the power supply with other voltages This device is likely to be damaged or damage other equipments / personnel, if you use a power supply with different voltage than the one included with this device. All warranty of this product will be voided in the situations above. z Don’t open the housing of the product z Cleaning Disconnect this video product from the power supply before cleaning.
z 1. When the power-supply cord or plug is damaged. 2. If liquid has been spilled, or objects have fallen into the video product. 3. If the video product has been exposed to rain or water directly. 4. If the video product does not operate normally by following the operating Instructions in this manual. Adjust only those controls that are covered by the instruction manual as an improper adjustment .
1.4 Physical Description Indoor High Speed Dome Bottom 1. Reset Button Step 1: Switch off IP device by disconnecting the power cable Step 2: Press and continue to hold the Reset Button. Reconnect the power cable while continuing to hold the reset button. Step 3: Keep holding the reset button depressed around 6 seconds, release the reset button. The unit will start up with factory default settings. 2.
Pin 4 Line Lock Pin 5 System Initialization (for upgrade) Pin 6 Reserved RS-232 is reserved for internal use only; The Pin 3 and Pin 4, they are used for termination and Link Lock adjustment respectively. The Pin 5 is mainly used for return to factory default of camera setting. 3. Dome ID Setting Use the switch to change your speed dome ID by turning the arrow to the desired number respectively.
Pelco P 14 9600 Select protocol: Pelco D, with switch no. 01 and baud rate 2400, for instance, the ID switch should be set as below: decimal single digit 5. 16 Pin Connector for LAN/WAN The LAN/WAN cable (shown as the figure below) is shipped with IP high speed dome. Please find it in the accessory bag. 6. 22 Pin Connector A 50cm data cable (shown as the figure below) is shipped with IP high speed dome. Please find it in the accessory bag.
1.5 Mounting the IP High Speed Dome Generally, there are three kinds of ceiling mounting methods: surface mount, in-ceiling mount, and mounting with straight tube. The surface mounting kit is shipped with IP high speed dome. For more detailed information, please refer to Appendix A.
1.6 Basic Connections Follow the procedures below to connect the IP high speed dome to the respective apparatuses.
Appendix A: Speed Dome Installation Basing on user’s installation environments, the dome can be installed on ceiling, on wall or on pole. In the following section, various indoor speed dome installation accessories, installation methods and installation procedures will be described in detail. A-1: Optional Accessories Surface Ceiling Mount For Surface Ceiling use. Height: 21.4mm ; Diameter of the three holes: 4.5mm ; Diameter of the bracket: 158mm In-Ceiling Mount For in-ceiling Installation use.
Ceiling Panel For ceiling mounting. Zn platted; 610×305 mm (24×12 inches); Diameter: 155 mm (6.1 inches) Transparent Cover/Smoke Cover Diameter: 137 mm (5.4 inches); 127 mm (5.0 inches) 5’’ Transparent Cover 5.4’’ Transparent Cover 5’’ Smoke Cover 5.4’’ Smoke Cover Indoor Mount Kit White; Diameter: 140 mm (5.5 inches); Height: 74 mm (2.9 inches) For mounting indoor dome camera onto a gooseneck/straight tube.
Mounting Accessories Gooseneck Tube White/Iron; 298×385 mm (11.73×15.56 inches) ; 2.1 kg (4.6 lbs) Supplied with rubber washer-8×1, pendant tube washer×1, spring washer-8×1 and waterproof rubber×1, M8*12 screw×1. Straight Tube White/Iron; Height: 250/500 mm (9.8/19.7 inches); Diameter: 50 mm (2 inches) 1 kg (2.2 lbs) / 1.8 kg (4 lbs). Supplied with rubber washer-8×1, pendant tube washer×1, spring washer-8×1 and waterproof rubber×1, M8*12 screw×1.
washer-8×4, spring washer×4, M8*20 screw×4, M8 nut×4. Pole Thin Direct Mounting White/Ivory; 232(L)×136(W)×60(D) mm (9.1×5.4×2.4 inches); Diameter: 112~140 mm (4.4~5.5 inches); 0.7 kg (1.6 lbs). Supplied with stainless steel straps×4, M8*16 screw×4, washer×4. Pole Wide Direct Mounting White/Ivory; 270(L)×170(W)×60(D) mm (10.6×6.7×2.4 inches); Diameter: 112~130 mm (4.4~5 inches); 1 kg (2.2 lbs).
Corner Thin Box White/Ivory, 300(L)×164(W)×222(D) mm (11.8×6.5×8.7 inches); 3 kg (6.7 lbs); Supplied with washer×4, M8*16 screw×4 and spring washer×4. Corner Wide Box White/Ivory; 232(L)×234(W)×210(D) mm (9.1×9.2×8.3 inches); 2.7 kg (6 lbs); Supplied with washer×4, M8*16 screw×4 and spring washer×4.
Pole Thin Box White/Ivory; 291(L)×136(W)×245(D) mm (11.5×5.3×9.5 inches); 3.1 kg (6.9 lbs); Supplied with M8*16 screw×4, washer×4, spring washer×4, stainless steel straps×4. Pole Wide Box White/Ivory, 270(L)×166(W)×155(D) mm (10.6×6.5×6.1 inches); 3.2 kg (7.1 lbs); Supplied with M8*16 screw×4, washer×4, spring washer×4, stainless steel straps×4. Wall Box Mounting Ivory, 270(L)×166(W)×95(D) (10.6×6.5×3.7 inches); 2.2 kg (4.
Stainless Steel Straps For fixing Pole Direct Mounting/ Pole Box on the pole. Width: 0.63”; 0.02 kg (0.04 lbs) Stainless Strap Cutter For tension, cut and crimp stainless steel straps. 1.4 kg (3.
D77R1 D77R2 D77R3 Connector Box (Indoor Application) Recommended for wiring indoor dome alarm cables. White Color. 92×42 mm (3.7×1.7 inches); 0.13 kg (0.3 lbs); Supplied with cable×1, bracket×1 and M3*6 screw×2. Power Box White; 186.5×147 mm (7.3×5.8 inches); 2.6 kg (5.
A-2: Ceiling Mount Generally, there are three kinds of speed dome camera ceiling mounting methods: surface mount, in-ceiling mount, and mounting with straight tube. Refer to the following sections for more detailed information. The following figures show how cables connect to the speed dome camera in different ways.
A-3: Surface Ceiling Mounting Surface Ceiling Mounting is a standard installation for an indoor dome, and general mounting accessories are equipped in the standard indoor dome camera package. Here lists the items and tools needed to mount the dome camera onto the ceilings. The supplied items are all in the speed dome camera package.
STEP 3 Attach the Mount to the ceiling. Mark the locations where all three ceiling holes should go. STEP 4 Drill these holes on the surface ceiling. STEP 5 Fix the Mount to the holes on the surface ceiling with three screws. STEP 6 Thread the data cable through the center hole of the Mount and connect the cable to the dome body.
STEP 7 Attach the dome body to the Mount and rotate the dome clockwise. Tighten the fixing screw to fix the dome body. STEP 8 Fix the decoration ring to the bracket and then place the optical cover. A-4: Ceiling Panel for In-ceiling Mounting To mount the speed dome camera to a suspended ceiling with the T-Bar, the ceiling panel could be employed, as shown in the figure below. Follow the steps below for installing the ceiling panel.
A-5: In-ceiling Mounting Here lists the items and tools needed to mount the dome camera into the ceilings. The supplied items are all in the dome camera package.
Step 2: Attach the separated wing to the dome, as shown in the diagram. STEP 3 Place the Red Sticker on the ceiling plate, and cut the circle part out of the ceiling. STEP 4 Put up the T-Bar into the ceiling hole. STEP 5 Rotate T-Bar wings of the hinge to fix the T-Bar at the edge of the ceiling hole.
STEP 6 Tighten the screws, and the T-Bar wings will adhere to the ceiling. STEP 7 Put the 22-pin data cable through the center hole of the T-bar and connect it to the dome body. STEP 8 Mount the dome body to the Bracket and rotate it clockwise. Tighten the fixing screw to fix the dome body. STEP 9 Fix the decoration ring to the bracket and then place the optical cover.
A-6: Ceiling Mount with Straight Tube The straight tube is available in different length: 25cm and 50cm. Follow the steps to mount the speed with the straight tube. (1) Ensure that the ceiling can support the weight of the speed dome camera and straight tube.
A-7: Wall Mount A-7-1 Wall Mounting with Gooseneck Tble The following figures show how cables run through the tube in different ways. Cables exposed Cables recessed Follow the steps to mount the speed dome with the gooseneck tube. (1) Make a cable entry hole on the wall to recess the cables. Otherwise, cables can be threaded through the cable entry hole on the tube.
A-7-2 Wall Box Mounting Follow the steps to mount the dome with the wall box and gooseneck tube. 1) Fix the wall box to wall. 2) Fasten the gooseneck tube on the wall box. 3) Thread the cables through the gooseneck tube and the Indoor Mount Kit and connect them to the dome camera. For installation of the cables, Indoor Mount kit and the dome camera unit, refer to A-7-1 as the steps are the same as for gooseneck mounting.
A-8: Corner Mount A-8-1 Corner Standard Mounting Plate With the corner mounting plate and gooseneck, the dome can be mounted on wall. There are various types of corner mounting accessories with different width. 1) Make a cable entry hole on the wall to recess the cables.
A-8-2 Corner Thin/Wide Box Mounting The thin/wide corner box is designed to be installed with a gooseneck tube. Follow the steps to mount the dome camera with the corner box and gooseneck tube. 1) Make a cable entry hole on the wall to recess the cables.
A-9: Pole Mount A-9-1 Pole Thin/Wide Direct Mounting The dome can be installed on a pole with a thin or wide pole mounting accessory and a gooseneck. 1) Fasten the suspension mounting plate on a pole with equipped stainless straps 2) Fix the gooseneck tube on the pole mounting plate 3) Thread the cables through the gooseneck tube and the Indoor Mount kit and connect them to the speed dome camera 4) Fix the Indoor Mount kit to the gooseneck tube using the screws and washers.
A-9-2 Pole Thin/Wide Box Mounting Follow the steps to mount the PTZ camera with the pole box and gooseneck tube. 1) Fasten the pole box on a pole with equipped stainless straps 2) Fix the gooseneck tube to the pole box 3) Thread the cables through the gooseneck tube and the top holder and connect them to the PTZ camera 4) Fix the top holder to the gooseneck tube using the screws and washers. 5) Attache the PTZ camera to the top holder and fix them with the screw.
Appendix B: OSD Menu Notes B-1: OSD Display Format The information shown on the screen are described in terms of OSD display, position and function description in the table below.
Item Layer 1 Layer 2 Layer 3 Default CAMERA BACKLIGHT , AUTO AF Mode , , FOCUS AE MODE OFF MANUAL Focus Manual Speed <01>~<08> AUTO Exposure Comp. , <1>~<15> BRIGHT Bright <0> ~ <31> SHUTTER Shutter Speed <1> ~ <1/10000> Sec. GAIN Gain <-3> ~ <28>dB IRIS Iris ,
Item Layer 1 Layer 2 Layer 3 Default SETTNG ALARM SWITCH , OFF ALARM TYPE (Normal Open), (Normal N.C. Close) ALARM ACTION PRESET ☆ SEQUENCE AUTOPAN CRUISE PRESET POINT <001> ~ <256> SEQUENCE LINE <1> ~ <8> AUTOPAN LINE <1> ~ <4> CRUISE LINE <1> DWELL TIME <001> ~ <127> Sec., EXIT YES HOME FUNC.
Item Layer 1 Layer 2 Layer 3 END POINT , DIRECTION , SPEED <01> ~ <04> Default Right 01 RUN AUTOPAN EXIT RECORD START RECORD END CRUISE RUN CRUISE EXIT IR FUNCTION (F/U model , Auto only) ALARM DETECT SWITCH , DETECT MODE , ,
Item Layer 1 Layer 2 SCHEDULE SW. , SCHEDULE <01> ~ <32> Layer 3 Default OFF 01 POINT SCHEDULE 00 HOUR SCHEDULE MIN 00 SCHEDULE NONE MODE PRESET ☆ SEQUENCE AUTOPAN SCHEDULE CRUISE IR FUNC.
Item Layer 1 Layer 2 Layer 3 MANUAL H APERTURE <00> ~ <31> Default V APERTURE <00> ~ <31> AUTO IRIS OFFSET <00> ~ <99> SHUTTER SHUTTER SPEED <1/2> ~ <1/30000> AE MODE IRIS IRIS <00> ~ <09> AGC AGC <00> ~ <05> ☆ AUTO WBC MODE 50 MANUAL R Gain <00> ~ <99> B Gain <00> ~ <99> ID DISPLAY , FLIP ON (K model only), , OFF SETUP MENU ZOOM SPEED , Slow SPEED BY ZOOM , OFF AUTO CALI.
Item Layer 1 Layer 2 Layer 3 PRESET POINT <001> ~ <256> SEQUENCE LINE <1> ~ <8> AUTOPAN LINE <1> ~ <4> CRUISE LINE <1> DWELL TIME <001> ~ <127> Sec., ALWAYS EXIT YES HOME FUNC. , SELECT MODE PRESET Default 001 ALWAYS OFF ☆ SEQUENCE AUTOPAN CRUISE HOME PRESET POINT <001> ~ <256> SETTING SEQUENCE LINE <1> ~ <8> AUTOPAN LINE <1> ~ <4> CRUISE LINE <1> RETURN TIME <001> ~ <128> Min.
Item Layer 1 Layer 2 Layer 3 Default RUN CRUISE EXIT AUTO THRESHOLD , , LOW IR FUNCTION IR COLOR (K model only) , B/W EXIT ON WDR SWITCH , WDR FUNCTION AUTO WDR OFF ☆ MANUA RATIO LEVEL L <000>~<128> SETTING SHUTTER LEVEL (K model only) <000>~<128> IRIS OFFSET <000>~<128> EXIT PRIVACY , OFF SHADE , , Gray SET MASK <1> ~ H CENTER <000> ~ <256> <8> V CENTER <000> ~ <256> SWITCH PRIVACY H SIZE <000> ~ <1
Item Layer 1 Layer 2 Layer 3 Default SWITCH SCHEDULE <01> ~ <32> 01 POINT SCHEDULE 00 HOUR SCHEDULE MIN 00 SCHEDULE NONE MODE PRESET ☆ SEQUENCE AUTOPAN CRUISE IR FUNC.
18x MODEL MAIN PAGE 1 DEFAULT CAMERA BACKLIGHT FOCUS AE MODE WBC MODE ID DISPLAY SETUP MENU1 SETUP MENU2 B-3-1 22x MODEL/23x MODEL MAIN PAGE 1 DEFAULT CAMERA BACKLIGHT FOCUS APERTURE AE MODE WBC MODE ID DISPLAY SETUP MENU OFF OFF AUTO AUTO AUTO ON OFF OFF AUTO AUTO AUTO AUTO ON ENTER DEFAULT CAMERA The “DEFAULT CAMERA” is used to restore the camera settings (e.g. Backlight/Focus/AE//WBC/Aperture). Once any one of the items is modified, the setting will become automatically.
B-3-3 FOCUS Automatically adjusts the focus position to maximize the high frequency content of the picture in a center measurement area, taking into consideration the high luminance and strong contrast components. The focus of the dome camera can be operated in two modes: Manual Focus mode and Auto Focus mode. Different settings for various models are described as follows. ¾ ♦ 18x MODEL AUTO The optimum focus is achieved by the internal digital circuit.
B-3-4 APERTURE Sharpness is the subjective evaluation of detail in the picture. With this “APEATURE” function, users can adjust the enhancement of the edges of objects in the picture. When shooting text, this function may help by making them sharper and achieve a better image. There are 32 levels of adjustment, the options are <00> ~ <31>, <00> represents “no enhancement”. ♦ AUTO The dome camera will assign a proper aperture value automatically for camera to achieve a better image.
internal brightness reference level through auto Exposure Comp. to control the brightness of camera. The value of Exposure Comp. is selectable from <0> to <16> and the gain varies from -10.5 dB to 10.5 dB. Each step is 1.5 dB; the Exposure Comp. vaue <7> is equal to gain value 0 dB. The camera will not compensate brightness when the Exposure Comp. is set to . The default setting is . ♦ BRIGHT The brightness control function adjusts IRIS and AGC gain using an internal algorithm.
to get consistent exposure. ♦ IRIS With this option, the IRIS priority is higher than SHUTTER and AGC; SHUTTER and AGC circuit will function automatically in cooperating with IRIS to get consistent exposure. If the IRIS is modified manually, the action of exposure compensation depends on the AGC circuit. ♦ AGC With this option, the AGC priority is higher than SHUTTER and IRIS; SHUTTER and IRIS circuit will function automatically in cooperating with AGC to get consistent exposure.
3200K Base mode ♦ OUTDOOR 5800K Base mode ♦ ATW Auto Tracing White Balance mode. The dome taking out the signals in a screen in the range from 2000K to 10000K. ♦ MANUAL In this mode, users can change the White Balance value manually; R gain and B gain are adjustable and range from 0 to 128. WBC MENU R GAIN B GAIN 50 50 ¾ ♦ 22x MODEL / 23x MODEL AUTO In this mode, white balance works within its colour temperature range and calculates the best-fit white balance.
monitor screen. ♦ OFF Hide the ID address of the selected dome. B-3-8 SETUP MENU Users can adjust camera lens model parameters under SETUP MENUs. Depending on the model of dome cameras, the SETUP MENUs are different. 18x MODEL SETUP MENU1 FLIP ZOOM SPEED SPEED BY ZOOM AUTO CALI. DIGITAL ZOOM SLOW SHUTTER ANGLE ADJUSTER RESET EXIT ENTER 1 OFF OFF 12 OFF ENTER YES YES SETUP MENU2 APERTURE MASK DISPLAY 01 FIRST 22x MODEL / 23x MODEL SETUP PAGE FLIP ZOOM SPEED SPEED BY ZOOM AUTO CALI.
User can track an object continuously when it passes through under dome camera with setting Flip to IMAGE (digital flip) or M.E. (mechanical flip). FLIP SETTING FLIP EXIT OFF YES IMAGE IMAGE represents digital IMAGE FLIP, enables users to keep tracking object seamlessly and no delay occurs in comparing with mechanical flip. NOTE: The Privacy Mask function will be automatically disabled if the Image Flip function is enabled, and “Masking will be disabled” will be displayed on the screen. M.E.
algorithm when zooming automatically. The larger zoom ratio leads the lower rotation speed. ♦ AUTO CALIBRATION There are one horizontal and one vertical infrared rays check points in each dome. When the dome camera position may be moved during installation or maintenance, the relative distance between the original set point and the check point has been changed. Enable the Auto Calibration function, the dome will automatically detect that and reset the point baack to the original position.
lux. ¾ 23x MODEL The shutter speed is adjustable on 23x MODEL. With the slowest shutter speed, users can see objects in a dark environment under 0.2 lux; or see a smooth video image with a higher shutter speed. The options are from <1/2> to <1/60>. ♦ ANGLE ADJUSTER The item is for adjusting the camera view angle. The ranges of view angle are changed in different FLIP mode: the angle ranges from -10° to +100° with ME FLIP and FLIP OFF modes, and from -10° ~ +190° with IMAGE FLIP mode.
SETUP MENU2 APERTURE MASK DISPLAY 01 FIRST ♦ APERTURE Under this setup menu, users can adjust the enhancement of the edges of objects in the picture. There are 16 levels of adjustment; the options are <01) ~ <16>, <01> represents “no enhancement”. When shooting text, this function may help by making them sharper. ♦ MASK DISPLAY In this item, users can set the occasion to display the Privacy Mask, which aims to avoid any intrusive monitoring.
♦ OFF When the TITLE DISPLAY is set , no title will be displayed on the screen even titles are set in advance. B-3-11 TITLE SETTING Up to 16 zone titles can be set with maximum 20 characters for each title; two mask zones are allowed to set in a view area. Users can name the zone titles with privacy mask ID numbers for future recognition. NOTE: For 23x MODEL, the available area for setting privacy mask is restricted within tilt angle 45°. Follow the steps to set a camera title.
B-3-12 ALARM SETTING The integrated high speed dome provides eight alarm inputs and two alarm outputs (N.O. and N.C.) to connect alarm devices. With this function, dome will cooperates with alarm system to catch the event images. For wiring, please refer to the installation guide and/or qualified service personnel. Alarm parameters can be set on this page. ALARM SETTING ALARM PIN ALARM SWITCH ALARM TYPE ALARM ACTION PRESET POINT DWELL TIME EXIT 1 OFF N.C.
♦ ALARM ACTION Select one of these modes that choose a kind of actions that should be executed when an alarm is triggered. The alarm actions can be set to execute the preset position, sequence, auto-pan or cruise function. ♦ PRESET Select a preset point where the dome should go when an alarm pin is triggered. SEQUENCE Select a sequence line that the speed dome camer should execute when alarm pin is triggered. The Sequence line should be defined prior in SEQENCE setup menu.
is the HOME function. HOME function allows constant and accurate monitoring, to avoid the speed dome stops or missing events. HOME SETTING HOME FUNCTION SELECT MODE PRESET POINT RETURN TIME GO EXIT OFF PRESET 001 001 ENTER YES ♦ HOME FUNCTION The item is used to enable or disable the HOME function. ♦ SELECT MODE Select one of the modes that the dome should execute when HOME function is enabled and the RETURN TIME is up. The options are , , and .
♦ GO If HOME function is enabled, the users are allowed to execute HOME function manually by selecting this item. ♦ EXIT Exit the HOME SETTING menu. B-3-14 SEQENCE The function executes pre-positioning of the pan, tilt, zoom and focus features in a certain sequence for a camera. Before set up this function, users must setup at least two preset points.
setup speed range is from 1 ~ 15. Refer to below table for more information. Speed 1 Speed 2 Speed 3 Speed 4 Speed 5 Speed 6 Speed 7 Speed 8 Speed 9 Speed 10 Speed 11 Speed 12 Speed 13 Speed 14 Speed 15 PAN (degree/sec.) 10 23 35 45 55 65 75 185 205 225 250 280 320 365 400 TILT (degree/sec.) 8 12 22 30 40 50 58 185 210 240 275 305 335 365 400 ♦ DWELL TIME The DWELL TIME is the duration time that the speed dome will stay at the sequence point, and the range is from <0> to <127> seconds.
AUTOPAN AUTOPAN LINE START POINT END POINT DIRECTION SPEED RUN AUTOPAN EXIT 1 TO FIND TO FIND RIGHT 1 ENTER YES ♦ AUTOPAN LINE There are four sets of auto-pan lines built in speed dome camera. Users are able to command the speed dome camera to do continuously panning without limit by setting the start point the same as endpoint. ♦ START POINT Follow the description to set the start position of the AUTOPAN path. 1.
♦ SPEED The item is for defining the speed dome camera rotation speed while running auto-pan. The speed is adjustable from 1 to 4; refer to the table below for details. Speed 1 Speed 2 Speed 3 Speed 4 PAN (degree/sec.) 10 23 35 45 ♦ RUN AUTOPAN After the setting is completed, select this item to manually execute the Auto-pan function. ♦ EXIT Exit the AUTOPAN setup menu. B-3-16 CRUISE A Cruise is a route of manual operations that can be stored and recalled to execute repeatedly.
♦ RECORD START Follow the description to record the CRUISE path. 1. Rotate the speed dome camera to a desired view area. The percentage of the memory buffer will be displayed on the screen. 2. Pan, tilt the dome camera to form a path. The zoom setting is only available with 18x MODEL. NOTE: Beware of the memory size when building the cruise path. After the percentage of the buffer becomes 100%, the path will not be recorded.
♦ ON Select the item to remove the IR cut filter. ¾ 23x MODEL IR FUNCTION THRESHOLD IR COLOR EXIT ♦ LOW COLOR YES AUTO The internal circuit will automatically decide the occasion to remove the IR cut filter according to the image brightness level. THRESHOLD The speed dome will remove the filter immediately when the threshold value is reached. The threshold options are , and . threshold indicates a higher sensitivity and can improve the reliability of lens.
♦ DETECT MODE Four alarm detect modes are provided for different application. INT. FOCUS The alarm will be triggered if the internal focus changes; and if the focus returns to the original position, the alarm will stop. FIX FOCUS If focus movement is detected, the alarm will be triggered, and the alarm stops when focus returns to the original position. Of the detected focus movement keeps changing for more than four seconds, the new focus position will be memorized as the reference and the alarm will stop.
WDR SETTING WDR SWITCH WDR FUNCTION EXIT OFF AUTO YES ♦ WDR SWITCH Enable or disable the WDR function with the item. ♦ WDR FUNCTION The item is used to define the WDR function mode. AUTO If select , the speed dome camera operates the WDR function automatically. MANUAL Users are allowed to adjust WDR function manually by defining the RATIO LEVEL, SHUTTER SPEED and IRIS OFFSET value. WDR MODE RATIO LEVEL SHUTTER SPEED IRIS OFFSET EXIT ♦ 000 000 000 YES EXIT Exit this setup menu.
¾ 18x MODEL PRIVACY MASK MENU PRIVACY SWITCH ON TRANSPARENCY OFF COLOR BLACK SET MASK 01 EXIT YES ♦ PRIVACY SWITCH User can enable or disable the Privacy Mask function through this item. ♦ TRANSPARENCY The colour of privacy mask can be set as transparent related to background image. Select to display transparent masks. ♦ COLOUR The colour of privacy mask can be set through this item. The available colours are black, heavy gray, light gray, white, red, green, blue, cyan, yellow and magenta.
H SIZE (00 ~ 80) User can adjust the horizontal size of privacy mask through this item. Set the H and V size to 0 can also delete the selected mask. V SIZE (00 ~ 60) User can adjust the vertical size of privacy mask through this item. Set the H and V size to 0 can also delete the selected mask. ♦ EXIT Exit this page. ¾ 23x MODEL PRIVACY PRIVACY SWITCH SHADE SET MASK MASK CLEAR+RESET MASK DISPLAY EXIT ON GRAY 01 01 FIRST YES ♦ PRIVACY SWITCH The item is used to enable or disable masking function.
H CENTER(000 ~ 256) The original center of mask zone is the center of screen. User can move the center of mask zone to another position through adjust this value. V CENTER(000 ~ 256) The original center of mask zone is the center of screen. User can move the center of mask zone to another position through adjust this value. H SIZE(000 ~ 127) User can adjust the horizontal size of privacy mask through this item. Set the H and V size to 0 can also delete the selected mask.
B-3-21 TIME FUNCTION The item is used to set the TIME related parameters of the integrated high speed dome. TIME SETTING TIME DISPLAY SET YEAR SET MONTH SET DAY SET HOUR SET MINUTE EXIT+SAVE OFF 05 10 02 12 12 YES ♦ TIME DISPLAY Select to display the Time information on screen, or not to display. ♦ YEAR / MONTH / DAY The items are for setting up the system date. ♦ HOUR / MINUTE This items are for setting up the system time. ♦ EXIT+SAVE Exit this page.
♦ SCHEDULE SWITCH Select to enable the Schedule function or to disable. ♦ SCHEDULE POINT Users are allowed to set up 32 schedule points. ♦ SCHEDULE HOUR / MINUTE The items are for setting up the time of schedule points. ♦ SCHEDULE MODE This is for setting the Schedule function of the selected schedule point; the options are as follows. NONE No function will be executed for the schedule by selecting the item. PRESET Select one of the defined preset points for the selected schedule.