TDS
Material Safety Data Sheet PhotoDeco activa
EC 1907/2006 EU830/2015
Rev 16/03/2016 (previous Oct 2015)
SECTION 5 : FIRE-FIGHTING MEASURES
5.1 EXTINGUISHING MEDIA:
In the case of fire in the surroundings, all extinguishing agents are allowed.
5.2 SPECIAL HAZARDS ARISING FROM THE SUBSTANCE OR MIXTURE:
Not applicable
5.3 ADVICE FOR FIREFIGHTERS:
Special protective equipment: Depending on magnitude of fire, heat-proof protective clothing may be required, appropriate
independent breathing apparatus, gloves, protective glasses or face masks and boots. If the fire-proof protective equipment is not
available or not used, combat fire from a sheltered position or at a safe distance. The standard EN469 provides a basic level of
protection for chemical incidents.
Other recommendations: Cool with water the tanks, cisterns or containers close to sources of heat or fire. Bear in mind the direction
of the wind. Do not allow fire-fighting residue to enter drains, sewers or water courses.
SECTION 6 : ACCIDENTAL RELEASE MEASURES
6.1 PERSONAL PRECAUTIONS, PROTECTIVE EQUIPMENT AND EMERGENCY PROCEDURES:
Avoid direct contact with this product. Avoid breathing vapours. Keep people without protection in opossition to the wind direction.
6.2 ENVIRONMENTAL PRECAUTIONS:
Avoid contamination of drains, surface or subterranean water and soil. In the case of large scale spills or when the product
contaminates lakes, rivers or sewages, inform the appropriate authorities in accordance with local regulations.
6.3 METHODS AND MATERIAL FOR CONTAINMENT AND CLEANING UP:
Contain and mop up spills with absorbent materials (sawdust, earth, sand, vermiculite, diatomaceous earth, etc..). Avoid use of
solvents.
Keep the remains in a closed container.
6.4 REFERENCE TO OTHER SECTIONS:
For contact information in case of emergency, see section 1.
For information on safe handling, see section 7.
For exposure controls and personal protection measures, see section 8.
For subsequent waste disposal, follow the recommendations in section 13.
SECTION 7 : HANDLING AND STORAGE
7.1 PRECAUTIONS FOR SAFE HANDLING:
Comply with the existing legislation on health and safety at work.
General recommendations:
Avoid any type of leakage or escape. Keep the container tightly closed.
Recommendations for the prevention of fire and explosion risks:
The product is not liable to ignite, deflagrate or explode, and does not sustain the combustion reaction by oxygen from air in the
environment in which it is, so it is not included in the scope of Directive 94/9/EC concerning equipment and protective systems intended
for use in potentially explosive atmospheres.. Also they are not applicable the provisions of the ITC MIE BT-29 on the detailed
requirements for electrical installations in locals with risk of fire or explosion
Recommendations for the prevention of toxicological risks:
Do not eat, drink or smoke in application and drying areas. After handling, wash hands with soap and water. For exposure controls and
personal protection measures, see section 8.
Recommendations for the prevention of environmental contamination:
It is not considered a danger to the environment. In the case of accidental spillage, follow the instructions indicated in section 6.
7.2 CONDITIONS FOR SAFE STORAGE, INCLUDING ANY INCOMPATIBILITIES:
Prevent unauthorized access. Keep out of reach of children. Keep away from sources of heat. If possible, avoid direct contact with
sunlight. In order to avoid leakages, the containers, after use, should be closed carefully and placed in a vertical position. For more
information, see section 10.
Class of store : According to current legislation.
Maximum storage period : 12. months
Temperature interval : min: 5. ºC, max: 40. ºC (recommended).
Incompatible materials: Keep away from oxidixing agents, from strongly alkaline and strongly acid materials.
Type of packaging: According to current legislation.
Limit quantity (Seveso III): Directive 96/82/EC~2003/105/EC:
Lower threshold: 50 tons , Upper threshold: 200 tons
7.3 SPECIFIC END USES:
For the use of this product do not exist particular recommendations apart from that already indicated.