Installation Guide

UV-48 Universal Vent
Installation Instructions
To properly install this Universal Dormer Vent, please follow these instructions.
1) When used as a Roof Exhaust Vent, cut a 1.5” x 46” slot just below the first row of shingles using
the following chart. (See View 1). When used as a Roof Intake Vent, cut the slot 1 foot up from
the bottom edge of the roof, from there installation instructions are the same.
Please note: if more than one Universal Vent is being installed, then the VENTS (not the slots)
must be spaced 4 inches apart when installed, to allow for roof water drainage.
2) Apply sealant under the top flange and along the side edges (See View 2). Then place the top
flange under the shingles placing it so that the slot is centered under the Universal Vent. Be sure
the Vent is correctly aligned with the slot before continuing. (See View 3)
3) When the Universal Vent is in its final position, the bottom flange should rest on top of the shin-
gles to ensure correct drainage. Do not use sealant on the bottom flange. (See View 2)
4) Attach the Universal Vent to the roof using (#8 x 1") screws
on the bottom flange, 6 " apart. (See
View 4)

Summary of content (1 pages)