Table 2: Scooter Controller Internal Diagnostics
Flash
code
Possible Cause Solution
1 The battery needs charging.
The battery voltage has dropped below
23.3 volts in neutral. Recharge
batteries.
2 Battery voltage is too low.
The battery has dropped past 16.5
volts and is not sufficient to allow safe
driving. Check the battery condition
and the connections.
3 Battery voltage too high
The battery has exceeded 32 volts.
Check the battery condition and the
connections.
4 Current limit time out
The motor current has reached too
high a value. Check the condition of
the motor and loom. Contact your
Service Agent.
5 Park brake fault Check park brake conditions.
6 Speed control out of neutral
Return speed pod to neutral and rest
system. Readjust the speed lever to
neutral if necessary. Contact your
Service Agent.
7 Speed control fault
Check speed pod wiring for open or
short circuits. Check speed pot set-up.
Contact your Service Agent.
8 Motor fault Contact your Service Agent.
9 Internal (controller) fault Contact your Service Agent.