Leading Therapy in a New Direction! User Manual Model 2090 OptiFlex 3 Continuous Passive Motion Unit
TABLE OF CONTENTS FOREWORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ABOUT OPTIFLEX CPM UNIT . . . . . . . . . . . . . . . . . . . . . . . . 24 Precautionary Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FOREWORD OptiFlex® 3 Continuous Passive Motion (CPM) Therapy Unit This manual has been written for the operators of the OptiFlex 3 Continuous Passive Motion (CPM) Therapy Unit. It contains general instructions for operation, precautionary instructions, and maintenance recommendations. In order to obtain maximum life and efficiency from your OptiFlex 3 CPM Unit, and to assist in the proper operation of the unit, read and understand this manual thoroughly.
ABOUT OPTIFLEX 3 CPM UNIT OptiFlex® 3 Continuous Passive Motion (CPM) Therapy Unit NOTE: Throughout this manual “NOTE” may be found. These Notes are helpful information to aid in the particular area or function being described. PRECAUTIONARY INSTRUCTIONS The precautionary instructions found in this section and throughout this manual are indicated by specific symbols. Understand these symbols and their definitions before operating this equipment.
ABOUT OPTIFLEX 3 CPM UNIT OptiFlex® 3 Continuous Passive Motion (CPM) Therapy Unit • Read, understand and practice the precautionary and operating • • • • • • • • • instructions found in this manual before operating or using the unit. Know the limitations and hazards associated with using the OptiFlex 3 Continuous Passive Motion (CPM) Therapy Unit. Observe any and all precautionary and operational decals placed on the unit. Only use OptiFlex 3 on firm, flat, level surfaces.
OptiFlex® 3 Continuous Passive Motion (CPM) Therapy Unit ABOUT OPTIFLEX 3 CPM UNIT • U.S. Federal law restricts this device to sale by, or on the order of, a • • • • • • • • • • • Exercise caution when using accessories and auxiliary devices such physician or licensed practitioner. Make certain that the unit is electrically grounded by connecting only to a grounded electrical service receptacle conforming to the applicable national and local electrical codes.
NOMENCLATURE OptiFlex® 3 Continuous Passive Motion (CPM) Therapy Unit UNIT FAMILIARIZATION Footplate Mounting Bracket Footplate Angle Adjustment Knob Footplate and Pendant Storage Knee Hinge Calf Length Adjustment Knob (One on Each Side) Calf Support Assembly Knee Potentiometer and Hinge Femur Hinge Assembly (One on Each Side) Footplate Angle Adjustment Knob Thigh Support Assembly Motor Cover Pendant (See Page 6) Transport and Storage Handle Thigh Adjustment Scale (cm) (One on Each Side) Unit Ba
NOMENCLATURE OptiFlex® 3 Continuous Passive Motion (CPM) Therapy Unit Oscillation Zone™ PENDANT FAMILIARIZATION Carriage will oscillate three times between the flexion angle and 10° less than the flexion angle. Fast Back™ Carriage will slow down within 15° of the flexion angle. Progressive ROM™ * Unit will automatically increase the programmed flexion angle by 1° every hour up to a maximum of 5° per day.
NOMENCLATURE OptiFlex® 3 Continuous Passive Motion (CPM) Therapy Unit PENDANT FUNCTIONS AND USE How to use: To view the extension/flexion delay time, press and hold the Extension/Flexion Delay button. You can set independent Delay times for extension and flexion. If an extension and or flexion delay time is required, simply hold down the Delay button and the Extension or Flexion button and use the Up or Down Arrows to adjust the time. All user input and feedback is provided through the pendant.
NOMENCLATURE OptiFlex® 3 Continuous Passive Motion (CPM) Therapy Unit PENDANT FUNCTIONS AND USE Start/Stop (Emergency Stop): Starts or stops the treatment. How to Use: Press the Start/Stop (Emergency Stop) button to begin or end the treatment. CHART 1 COMFORT ZONE NOTE: When unit is stopped and the Start/Stop (Emergency Stop) button is pressed, the unit will immediately begin moving in the opposite direction of the last movement. C = Comfort Zone activated temporary flexion limit established.
NOMENCLATURE OptiFlex® 3 Continuous Passive Motion (CPM) Therapy Unit PENDANT FUNCTIONS AND USE Mode: Used together with Fast Back™, Oscillation Zone™ and Progressive ROM button to enable and disable the appropriate mode. All three modes or any combination may be used at once. CHART 2 FAST BACK How to Use: Press Mode button along with desired function (Fast Back, Oscillation Zone and/or Progressive ROM).
NOMENCLATURE OptiFlex® 3 Continuous Passive Motion (CPM) Therapy Unit PENDANT FUNCTIONS AND USE Progressive ROM™: When Progressive ROM is activated, the unit will automatically increase the Programmed Flexion Angle by 1° every hour, up to a maximum of 5° per 24 hour period. See Chart 4. How to Use: Press and hold the Mode button. Press the Progressive ROM button to enable the Progressive ROM mode.
NOMENCLATURE OptiFlex® 3 Continuous Passive Motion (CPM) Therapy Unit PENDANT FUNCTIONS AND USE Independent Delay Time You can set independent Delay times for extension and flexion. If an extension and or flexion delay time is required, simply hold down the Delay button and the Extension or Flexion button and use the Up or Down Arrows to adjust the time.
SPECIFICATIONS OptiFlex® 3 Continuous Passive Motion (CPM) Therapy Unit TECHNICAL SPECIFICATIONS ADDITIONAL DEFINITIONS: MODEL 2090 Input: Weight: 100 - 240 VAC~50/60 Hz, 75 VA 27 lbs (12 kg) Length: 37 in (94 cm) Electrical Class: Class I, Type B ROM- “Range Of Motion”. Operation Knee Flexion ROM Limit: Knee Extension Limit: 120° 10° Hyper Extension Knee Speed Range : 30°/min. to 150°/min.
SETUP OptiFlex® 3 Continuous Passive Motion (CPM) Therapy Unit UNIT PLACEMENT AND SOFTGOODS INSTALLATION 1. Place the unit on a level surface. • Place the unit on a level surface. Use of the unit on unstable • • surfaces do not give the stability the unit requires. If the unit becomes unstable, serious injury to the patient may occur. The Softgoods Kit is for single patient use only. A new Softgoods Kit must be used for each new patient.
SETUP OptiFlex® 3 Continuous Passive Motion (CPM) Therapy Unit NEW PATIENT SETUP Reset Pendant Adjust OptiFlex Femur Component Depress the Reset on the Pendant (i.e. paper clip, pen, etc.). With Reset depressed, press the Mode Button. Loosen the Thigh Adjustment Scale Knobs on each side of the unit. Raise or lower the unit to the measured distance. Tighten the Thigh Adjustment Scale Knobs. The Unit is now ready for new patient parameter input. Refer to pages 7 through 11.
SETUP OptiFlex® 3 Continuous Passive Motion (CPM) Therapy Unit NEW PATIENT SETUP Comfort Zone™ Securing Patient If the patient experiences discomfort, the Comfort Zone button may be pressed and the carriage will immediately reverse direction and move toward the extension angle. For the next five cycles, the carriage will operate in a range 5° less than the angle where the button was pressed.
SETUP OptiFlex® 3 Continuous Passive Motion (CPM) Therapy Unit PEDIATRIC FOOTPLATE SETUP Pediatric Footplate Loosen the footplate adjustment knobs and rotate footplate support as shown. Tighten the footplate adjustment knobs. Remove footplate from unit. Lay aside for re-installation. Re-install footplate. Loosen the tibial adjustment knobs and pull out the footplate assembly.
TROUBLESHOOTING OptiFlex® 3 Continuous Passive Motion (CPM) Therapy Unit The OptiFlex 3 CPM Therapy Unit is designed with patient safety in mind. An error can be caused by both external and internal disturbances. Before calling for service, carefully review this operator’s guide. In the event you are still unable to correct the problem, contact your Chattanooga Group dealer for all repair service. Be certain to specify your serial number and a detailed description of the issue you encountered.
MAINTENANCE OptiFlex® 3 Continuous Passive Motion (CPM) Therapy Unit CLEANING After each use, clean the unit using a soft cloth dampened with water and a mild antibacterial detergent. SERVICE Should the OptiFlex 3 CPM unit require service, contact the selling dealer or Chattanooga Group Service Department. All returned units to the factory for service must include the following: WARRANTY REPAIR/OUT OF WARRANTY REPAIR 1.
WARRANTY OptiFlex® 3 Continuous Passive Motion (CPM) Therapy Unit Chattanooga Group (“Company”) warrants that the OptiFlex 3 Model 2090 Continuous Passive Motion (CPM) therapy unit (“Product”) is free of defects in material and workmanship. This warranty shall remain in effect for two years (24 months) from the date of original consumer purchase.