User Manual

573904 | REV. B | 03.2016
Bosch Automotive Service Solutions Inc.
CP9670 AutoScanner®
|
User guide | 29
|
en
5.11 Diagnostic Monitor Tests
The Diagnostic Monitor Test function is useful after
servicing or after erasing a vehicle’s memory. Test results
do not necessarily indicate a faulty component or system.
Non-CAN vehicles Diagnostic Monitor Test receives test
results for emission-related powertrain components
and systems that are not continuously monitored.
CAN vehicles Diagnostic Monitor Test receives test
results for emission-related powertrain components and
systems that are and are not continuously monitored.
Vehicle manufacturer is responsible for assigning
test and component IDs.
From Diagnostic Menu:
1. Select Diagnostic Monitor Test.
Use the and keys until Diagnostic
Monitor Test is highlighted.
Press .
Diagnostic Menu
MIL Status
State OBD Check
View Data
Record Data
View Freeze Data
Drive Cycle Monitor
O2 Monitor Tests
Diagnostic Monitor Tests
On-Board Systems
Rd\Er
Applicable diagnostic monitor tests are displayed.
2. Review test results displayed on scan tool.
Use the and keys until desired result is
highlighted.
Press .
Non-CAN example:
Select Diag Mon Test
Test $49
Test $4A
Test $62
Test $76
Test $78
Test $81
Test $9A
Test $9B
Test $03
Rd\Er
CAN example:
Select Diag Mon Test
O2 Sensor B1S2
Catalyst B1
Purge Flow Mon
HO2 Sen B1S2
Misfire Data
Misfire Cyl 1
Misfire Cyl 2
Misfire Cyl 3
O2 Sensor B1S1
Rd\Er
Or, refer to appropriate vehicle service manual for
test IDs and definitions.
On Non-CAN vehicles the scan tool displays:
Test data (test ID)
Maximum value (MAX)
Test measurements (MEAS)
Minimum value (MIN)
Status (STS)
Measurements and Specification values are
hexadecimal numbers (i.e., $1A, $FE, $11.)
Module (MOD)
Test $03
MOD
MAX
MEAS
MIN
ID
$09
----
00
00
STS OK
01
Rd\Er
On CAN vehicles scan tool displays:
Test performed. The test performed can be
$## if test is not defined. Refer to vehicle
service manual for details.
Measured values and units of measured
(such as volts, amps, and seconds).
Status of monitor test data.
Module ID where the monitor test data
came from.
Purge Flow Mon
MOD $00
MAX 32.767(KPa)
MEAS 0.110(KPa)
MIN 0.000(KPa)
STS OK
Test $C9
Rd\Er
3. Return to Select Test menu.
Press .