User`s manual
10
 © Copyright ActSafe Systems AB 
SAFETY
Rope system safety
The rope system must consist of a primary-
rope (1) and a secondary back-up rope 
(2), both must be approved according to 
EN1891 and have a diameter of 10-13mm.
The two ropes must have separate 
anchor points that must hold at least 15 kN 
each. A competent person shall judge if the 
separate anchor points are sucient.
National regulations may require more. 
The product ascends on the primary rope. If 
any part of the load carrying system should 
break then the load is immediately transfer-
red to the secondary rope which, together 
with the fall arrester (3) according to EN 
353-2, provides a fall arrest system.
Rope characteristics are an important 
issue when using the ascender. Ropes with 
characteristics not suitable for the ascender 
might, in the worst-case scenario, result in a 
jam between the rope grab and the knife,
with a damaged rope as a consequence.
3
1
2
Do not use the Ascender without a backup
system.
The lifting capacity of the ascender is higher 
than the Safe Working Load (SWL) of the most
common fall arrest devices. Therefore, when
lifting a load it may be necessary with separate 
fall arrest system(s) for the load. See the user’s 
manual of the fall arrest device to nd out the 
SWL.
DANGER
The dead rope must be unloaded. Do not build 
cableways using the primary rope as shown in 
the picture.