USAGE
Connect to rope
1. Place the ascender on the ground.
2. Open the rope cover.
4. Put the rope around the rope grab.
5. Close the rope cover.
3. Form a loop on the rope and 
push it through the rope guide 
just above the rope grab.
6. Connect the primary connection 
karabiner to the EN 813 connection 
point of the full body harness and 
check the karabiner is locked.
Check that the live rope exits to the left 
and that the rope cover is fully closed.
Attaching the rope incorrectly can result 
in serious injury or death. Always use the 
ascender with a backup rope system.
Make sure that the rope is attached correctly
before use.
DANGER
Be careful handling the ascender with the
engine running - there is a risk of accidental
lifting without being properly attached.
If the ascender is connected to the rope and not 
the operator; pay attention starting the engine 
as it can accidentally ascend a short distance on 
the rope before the engine is warm.
Drive the ascender to waist level to simplify
connection to harness.