Emergency descent
Stay connected to your backup rope sys-
tem during all these steps. In the pictures 
the backup system is excluded for clarity.
Use the equipment in the rescue kit.
1.  Attach the Descender to the rope under 
the ascender and connect it to the 
harness with the attached red karabiner. 
Ensure that the Descender have been 
threaded correctly.
1
2-4
2.  Attach the rope clamp (blue karabiner) 
to the live rope above the ascender 
(approx. 10 cm).
3.  Connect the rope clamp to the harness 
with the red karabiner on the shorter 
sling.
4.  Tighten the short sling by pushing 
the rope clamp up.
The connection to the live rope is now formed 
by the rope clamp that is attached to the 
harness by the short sling.
5.  Release the rope from the rope grab.
The Ascender is now loose and you are 
connected to the rope clamp, the Descender 
and your backup system.
Have sucient rope slack (approx 0.5 m)
between the Ascender and the Descender
so you can work easily.