Owner manual

TROUBLESHOOTING
DRO 200E
35
If the problem remains in the same display, the readout is in error.
If the problem follows the connection change, the linear scale may be in error.
Refer to the Checking the Linear Scales section of your scale reference manual.
Display overflow errors are indicated by dashes in all digits in an axis display. A
numeric overflow occurs when the intended measurement is too large for the eight-
digit display. Clear the error by returning the machine table into an area where
measurements can again be displayed, selecting a lower display resolution, setting a
new preset, or zeroing the display.
This error may also occur when using the automatic compensation routine while
setting the LEC parameter. An error indicates that the calculated compensation fac-
tor was outside the acceptable range of -9999 to +9999, and usually is the result of
incorrectly entering data. Clear the error and return to the beginning of the linear
error compensation routine. Refer to page 19.
Data Logging
The readout collects information about itself while it is being used. This information
is stored in memory for review at a later time.
Press and hold the
.
key until the software version is displayed. Then press
the
S
and
M
keys simultaneously. Use the
X
key to cycle through the follow-
ing information.
Power on time - displayed in decimal hours.
Scale travel distance - the travel distance for each axis is scrolled one after the
other.
Last 3 errors - the most recent three errors are remembered and messages for the
errors are scrolled one after the other.