13. Move the axis to align reading head mounting holes.
14. A gap must exist between the reading head and the 
mounting surface.
15. Adjust the leveling screws, using a .001" -.003" feeler
gage (or shim) between the leveling screw and the
mounting surface. Adjust the leveling screw until a slight 
drag is felt on the feeler gage. Repeat this for each leveling 
screw, 3 total.
16. Evenly tighten the two 8-32 SHCS to secure the reading 
head.
17. Use the Allen wrench from the leveling screw adjustment to 
slide brackets away from the reading head.
18. Remove the alignment brackets and save with this Reference 
manual.
19. Route cable with slack loops allowing for axis motion.
20. Secure excess cable by fastening with clips and ties.
21. Move the axis through its full travel. Confirm that the 
assembly does not interfere with the machine movement.