Instruction Manual

PROGRAM STEPS
MILLPWR
®
Operation Manual
5-61
Delete Steps
MILLPWR gives you the option of deleting steps in two ways: using the DELETE STEPS
softkey or using the CANCEL key.
When deleting single steps, we suggest highlighting the step then pressing the
CANCEL key.
When deleting a range of steps—after you have merged programs, for example—the
"Delete Steps" feature is usually the best option.
T
o delete a group of steps from your program:
From the PGM screen, press the STEP FUNCTIONS softkey.
Press the
DELETE STEPS softkey.
In the “Step Range” field, enter the first and last step numbers that you would like
to delete.
Press the
USE key.