Feed Rate Settings
Here you can change the default settings for various speeds and feeds:
STEP OVERRIDE % determines the percentage of change that occurs
when you press the FEED+ and FEED- keys.
MAX % establishes the maximum feed rate percentage that the FEED+
key will allow.
MIN
% establishes the lowest feed rate percentage that the
FEED- key
will allow.
DRY RUN SPEED is the speed that the table will move during a dry run.
DEFAULT FEED RATE enables you to define the default feed rate for all
milling functions—this way, if you forget to enter a feed rate,
MILLPWR will automatically apply the default feed rate to the milling function. It is suggested
that you set the default feed rate to the rate that you use most often.
UNIT/(MIN) lets you define the feed rate in either inches per minute or millimeters per
minute.
FULL CUT FEED RATE % is the percentage of the programmed feed rate used when the tool
is making a full cut (e.g., the beginning cut in a pocket).