Safety Instructions

2 of 3
rPP20 Relay Pack
POWER/RELAY PACK
FAMILY INSTRUCTIONS
Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitycontrols.com © 2019 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/08/2020
912-00056-002 FCC ID: 2ADCB-RMODIT IC: 6715C-RMODIT IFETEL: RCPACRM18-1879 Acuity Brands Lighting Inc. RMODIT
INSTALLATION INSTRUCTIONS
OVERVIEW
INITIAL OPERATION
TROUBLESHOOTING TIPS
For further troubleshooting guidance, please contact the Controls Technical Support Team
1(800)-535-2465
REQUIRED TOOLS & SUPPLIES
Chicago Plenum Device
Electical Pliers
Screwdriver
Wire nuts
Electrical box
2mm Precision Slotted Screwdriver, used for 24V terminals only
1. Turn power off at circuit breaker.
2. Install electrical box in accordance with state, local and national
electrical codes and requirements.
3. Remove knock-out from side of electrical box.
4. Remove retaining nut and washer from power pack mounting
nipple.
5. Feed Class 1* wires and mounting nipple through knockout hole.
6. Install washer and thread retaining nut onto nipple, and hand-
tighten to wall of electrical box, then apply additional quarter-turn
tightening with pliers.
7. Using wire nuts, connect line and low voltage wires as shown in the
applicable wiring diagram in accordance to state, local and national
codes and requirements.
8. “24V” models only: Connect +/- DC power leads from nLight AIR
sensor(s) to 24VDC terminal block on side of rPP enclosure, if
needed. See diagrams below for additional details.
9. For Chicago Plenum models only: Connect the antenna with the
gasket to the inside of the sealed box, with the retaining nut on the
outside of the box, as illustrated. Once installed, the antenna is IP
67 rated.
10. Install electical box cover plate before restoring power.
*DS option provides Class 2 low voltage dimming wires
on side of enclosure opposite from chase nipple.
*For Chicago Plenum option, see step 9 .
INSTALLATION STEPS
Following power up, the relay shall close to energize the load. The dimming output shall be at 100% light output. The device shall remain in this state until programmed
with Clairity Pro mobile application. See Clairity Pro User Guide for additional programming information.
For Emergency Variant ER
The RPP/RPP20 ER version is a UL924 listed device that is powered on the Emergency circuit and provides full light output (at user-defined high-trim level) in absense of
AC voltage on Normal Power sense leads. Normal operation of the control device is restored when AC line voltage is restored to the normal power sensing leads.
Device cannot be viewed in Clairity Pro
1. Press user button for specified time to reset the device to place the device in Maintenance Mode
2. Once the user-button LED confirms that the RP20 is in Maintenance Mode, open the Clairity Pro application and search for the device in Clairity Pro.
a. If you still cannot see the device in Clairity Pro, contact Technical Support for additional assistance; device may need to be replaced.
3. Once the device is identifiable Clairity Pro, attempt to group or configure the device. If you are still having issues, refer to the Clairity Pro User Manual or contact Technical
Support for assistance using Clairity Pro to complete programming of your device.
nLight AIR rPP/rPP20 is a device that provides on/off switching and dimming for light fixtures. It is suitable for control of commercial and industrial light fixtures in
indoor environments. When installed as part of an nLight AIR lighting control system, the rPP/rPP20 will respond to wireless commands from other devices, to be
programmed during startup.