8.5.4.21 reportreadcount - Reports the amount of tag reading
Command
reportreadcount value
Function
Check (no value) or change the sending of the read amount of the tag.
Description
Enables or disables sending the read amount of the tag in the "rfon" period in the result
string.
Pattern
Off
Values
on
off
Notes
The maximum value of the read amount is 255.
Example
To check the value:
reportreadcount<CR>
off<CR>
To change the value to have the amount of reading in the result string:
reportreadcount on<CR>
ok - parameter has been changed.<CR>
Errors
When the value reported is not among the specified:
error - value out of range<CR>
When more than one value is passed to the command: