Repair Service Manual

REPAIR MANUAL
3
REGULATOR ASSEMBLY
After removing the sliding flange from the fixed flange shaft,
position the latter on the removal tool in order to lower the upper
main bearing (11).
Lower the upper main bearing (11) to be able to remove the
retaining ring (12) with a flat blade screwdriver.
Rise the sliding flange slowly to remove it. Avoid dropping parts if
removing is performed with a table press.
According to the pulley’s adjustment, please note that
you must carefully observe the quantity and position of the
spacer washers (5-6-7) and (9-10) to avoid modifying the
initial yield of the pulley.
Cleaning the sliding parts with a degreaser is indispensable
to maintain optimum performance.
Inspection
Damage to the main bearings 4 and 11
Wear of the flange (by belt friction)
Damage to the spring (8)