3
REGULATOR ASSEMBLY
Removing the fixed flange (if required)
1 Fixed flange
1a Bearing
1b Tightening ring
Before each part removing step, clean the shaft carefully.
Using a puller is required to prevent damaging the parts which do not
require changing.
Removing the tightening ring (1b)
Removing the bearing (1a)
Inspection
Shaft damage. (inside and outside)
Wear of the flange (by belt friction)
Change the bearing (1a), if required