3
REGULATOR ASSEMBLY
Fixed flange
The fixed flange (1) is not removable without damaging
the parts.
Just perform an inspection.
Inspection
Shaft deterioration (internal and external)
Wear of the flange (by belt friction)
Visual inspection.
Refitting the led pulley
Fitting the cam sliders on the sliding flask
Fitting cam sliders (3) can be performed using a
hammer.
Ensure you do not damage the sliders by excessive use of the hammer.
Fitting the spring onto the sliding flange
Position the spring (4) in the sliding flange (2) at the
position noted during removal.
Position the key (5) on the shaft of the fixed flange (1).