ELECTRICITY-INSTRUMENTS
Maintenance «Reset»:
Maintenance can be reset at any time, except when the maintenance mileage or time has been
exceeded.
To perform a reset: Turn the ignition and wait for the dashboard to be in normal operation (do not
exceed 15 sec.) Right after, hold the two buttons pressed (right and left) for 6 seconds.
The « rESEt » message appears on the left-hand display.
Outside temperature indication function:
The outside temperature operates from a resistive sensor (CTN) with a nominal resistor R25 = 5K
±1% and a constant B25/50 = 3470K ±1%.
Displaying the outside temperature is possible only on models
with two LCD. It appears in the right-hand LCD.
The display unit is always degrees Celsius (ºC).
The display on the right-hand LCD has the negative sign + 2
digits + the ºC symbol.
Display accuracy is ±1ºC.
Warning when outer lower temperature below +3ºC. In this
condition, the display flashes.
If the sensor is not connected (circuit open) or if the sensor is in
short-circuit, there is no display.