Troubleshooting guide

PROGRAMMING
MILLPWR
®
Operation Manual
3-9
Using an electronic edge finder:
From the DRO screen, press the
SKEW softkey.
Touch off on two or more points along any single straight edge of your part. You’ll
notice that the “Points” and “Angle” change as you enter points.
Press
USE to accept all of the points and return to the DRO screen. Press CANCEL to
return to the DRO screen without accepting any points or affecting your previous
skew angle.
The
CLEAR ANGLE softkey will reset the number of points and the skew angle to zero.
Using teach position:
From the DRO screen, press the
SKEW softkey.
Move the table so that a mechanical indicator rests against any straight edge
on the
part. Press the TEACH POSITION softkey to enter your coordinate.You’ll notice that the
“Points” change.
Now move the table so that the mechanical indicator touches another point on the same
straight edge. Press the
TEACH POSITION softkey. You’ll notice that the “Points” and
“Angle” change.
Repeat this process for any additional points.
Press
USE to accept all of the points and return to the DRO screen. Press CANCEL to
return to the previous screen without affecting your previous skew angle.
The
CLEAR ANGLE softkey will reset the number of points and the angle to zero.