Troubleshooting guide
DEMONSTRATION
MILLPWR
®
Operation Manual
4-20
Tool Changes
Whenever you encounter a SET TOOL step, MILLPWR will display the DRO screen and let
you know which tool to load. If no tool diameter was programmed in the “Tool Step,” you
will be prompted to provide one.
• Use the
MOVE TABLE softkey and arrow keys to move the tool
away from your workpiece.
• Insert the required tool into the spindle.
• Using the
MOVE TABLE feature, position the tool over
the surface of a known depth on your workpiece.
• Press the
DATUM softkey.
• Position your tool so that it touches a known surface,
then enter that position into the Z-axis.
• Press the
USE key.
• Raise the tool and press the
GO key to continue the program.
Clearing the Program
• From the PGM screen, press the CLEAR softkey.
• Press the
YES softkey. The PGM screen will be cleared and ready
for another program.
If the surface is
at datum 0, use
the Z = 0 soft-
key.