DHW CONNECTION
General remark
The circuit illustrations are basic principle diagrams only.
Essential recommendation for safety
The hot water output may reach temperatures in excess of 60°C, which can cause
scalding! It is therefore necessary to install a thermostatic mixing valve after the
appliance.
Essential recommendations for the correct operation of the appliance
Flush the system before connecting the domestic hot water circuit. Refer to the
installation instructions.
Make sure to install a pressure reducing valve set at 4.5 bar if the mains supply
pressure is in excess of 6 bar.
The installation must be fitted with an approved safety group, comprised of a 7 bar
safety valve, a check valve and a shut-off valve.
Typical installation
Description
1. Isolating valve
2. Pressure reducing valve
3. Check valve
4. DHW expansion vessel
5. Safety valve
6. Drain valve
7. Draw-off tap
8. Grounding
9. Thermostatic mixing valve
Cold water
Hot water
1 2 3
1
1
8
4
5
6
7
9
EN
23
EN
BNE : 664Y6000 •D