Datasheet

LSM303DLHC Register description
Doc ID 018771 Rev 1 35/42
7.1.24 CLICK_THS_A (3Ah)
1 LSB = full-scale / 128. THS6 through THS0 define the threshold which is used by the
system to start the click detection procedure. The threshold value is expressed over 7 bits
as an unsigned number.
7.1.25 TIME_LIMIT_A (3Bh)
1 LSB = 1/ODR. TLI7 through TLI0 define the maximum time interval that can elapse
between the start of the click detection procedure (the acceleration on the selected channel
exceeds the programmed threshold) and when the acceleration goes back below the
threshold.
7.1.26 TIME_LATENCY_A (3Ch)
Z Z CLICK-CLICK detection. Default value: 0
(0: no interrupt, 1: Z high event has occurred)
Y Y CLICK-CLICK detection. Default value: 0
(0: no interrupt, 1: Y high event has occurred)
X X CLICK-CLICK detection. Default value: 0
(0: no interrupt, 1: X high event has occurred)
Table 61. CLICK_SRC_A description (continued)
Table 62. CLICK_THS_A register
-- Ths6 Ths5 Ths4 Ths3 Ths2 Ths1 Ths0
Table 63. CLICK_SRC_A description
Ths6-Ths0 CLICK-CLICK threshold. Default value: 000 0000
Table 64. TIME_LIMIT_A register
-- TLI6 TLI5 TLI4 TLI3 TLI2 TLI1 TLI0
Table 65. TIME_LIMIT_A description
TLI7-TLI0 CLICK-CLICK time limit. Default value: 000 0000
Table 66. TIME_LATENCY_A register
TLA7 TLA6 TLA5 TLA4 TLA3 TLA2 TLA1 TLA0
Table 67. TIME_LATENCY_A description
TLA7-TLA0 CLICK-CLICK time latency. Default value: 000 0000