Datasheet
100
3V 1V-
´
(I atV =1V)
Xn OUTXnOLC
(I atV =3V) (I atV =1V)-
OLCXn OUTXn OLCXn OUTXn
D (%/V)=
100
(I atVCC=3V)
Xn
OLC
(I atVCC=5.5V) (I atVCC=3V)
Xn Xn
-
OLC OLC
5.5V 3V-
D (%/V)=
´
I (mA)=41 ´
Xn(IDEAL)OLC
1.21
R
IREF
( )W
D (%)=
IdealOutputCurrent
- (IdealOutputCurrent)
(I +I +I +I )
X0 X1 X2 X3OLC OLC OLC OLC
4
´ 100
D (%)=
- 1
I
XnOLC
(I +I +I +I )
X0 X1 X3X2OLC OLC OLC OLC
4
´ 100
TLC59711
www.ti.com
SBVS181A –OCTOBER 2011–REVISED JULY 2012
ELECTRICAL CHARACTERISTICS (continued)
At T
A
= –40°C to +85°C, V
CC
= 4 V to 17 V or V
CC
= V
REG
= 3 V to 5.5 V, V
LED
= 5 V, and C
VREG
= 1 µF, unless otherwise
noted. Typical values are at T
A
= +25°C and V
CC
= 12 V.
TLC59711
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Constant-current error
(1)
All OUTXn on, BCX = 7Fh, V
OUTXn
= V
OUTfix
= 1 V,
ΔI
OLC
(channel-to-channel in same color group), ±1 ±3 %
R
IREF
= 0.82 kΩ (I
OLCMax
= 60 mA)
OUTXn
Constant current error
(2)
All OUTXn on, BCX = 7Fh, V
OUTXn
= V
OUTfix
= 1V,
ΔI
OLC1
(device-to-device in same color group), R
IREF
= 0.82 kΩ (I
OLCMax
= 60 mA), at same grouped color output ±1 ±4 %
OUTXn of OUTR0-3, OUTG0-3, and OUTB0-3
Line regulation of constant-current output, All OUTn on, BCX = 7Fh, V
OUTXn
= V
OUTfix
= 1 V,
ΔI
OLC2
±0.5 ±1 %/V
OUTXn
(3)
R
IREF
= 0.82 kΩ (I
OLCMax
= 60 mA)
Load regulation of constant-current output, All OUTn on, BCX = 7Fh, V
OUTXn
= V
OUTfix
= 1 V,
ΔI
OLC3
±1 ±3 %/V
OUTXn
(4)
R
IREF
= 0.82 kΩ (I
OLCMax
= 60 mA)
T
TSD
Thermal shutdown temperature Junction temperature
(5)
150 165 180 °C
T
HYS
Thermal shutdown hysteresis Junction temperature
(5)
5 10 20 °C
V
IREF
Reference voltage output, IREF R
IREF
= 0.82 kΩ 1.18 1.21 1.24 V
V
REG
Linear regulator output voltage, VREG V
CC
= 4 V to 17 V, I
REG
= 0 mA to –25 mA 3.1 3.3 3.5 V
ΔV
REG
Line regulation of linear regulator, VREG V
CC
= 4 V to 17 V, I
REG
= 0 mA 90 mV
ΔV
REG1
Load regulation of linear regulator, VREG V
CC
= 12 V, I
REG
= 0 mA to –25 mA 120 mV
V
STR
Undervoltage lockout release, VREG 2.5 2.7 2.9 V
V
HYS
Undervoltage lockout hysteresis, VREG 300 400 500 mV
(1) The deviation of each output in the same color group (OUTR0-OUTR3 or OUTG0-OUTG3 or OUTB0-OUTB3) from the average current
from the same color group. Deviation is calculated by the formula:
Where: X = R/G/B, and n = 0-3
(2) The deviation of each color group constant-current average from the ideal constant-current value.
Deviation is calculated by the following formula:
Where: X = R/G/B.
Ideal current is calculated by the following formula for the OUTRn and OUTGn groups:
Where: X = R/G/B.
(3) Line regulation is calculated by this equation:
Where: X = R/G/B, n = 0-3.
(4) Load regulation is calculated by the equation:
Where: X = R/G/B, n = 0-3.
(5) Not tested, specified by design.
Copyright © 2011–2012, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Link(s): TLC59711