Data Sheet
a-Si TFT LCD Single Chip Driver
240RGBx320 Resolution and 262K color
ILI9341
The information contained herein is the exclusive property of ILI Technology Corp. and shall not be distributed,
reproduced, or disclosed in whole or in part without prior written permission of ILI Technology Corp.
Page 101 of 233
8.2.12. Sleep Out (11h)
11h SLPOUT (Sleep Out)
D/CX RDX WRX D17-8 D7 D6 D5 D4 D3 D2 D1 D0 HEX
Command
0 1
↑
XX 0 0 0 1 0 0 0 1 11h
Parameter
No Parameter
Description
This command turns off sleep mode.
In this mode e.g. the DC/DC converter is enabled, Internal oscillator is started, and panel scanning is started.
X = Don’t care
Restriction
This command has no effect when module is already in sleep out mode. Sleep Out Mode can only be left by the Sleep In
Command (10h). It will be necessary to wait 5msec before sending next command, this is to allow time for the supply voltages
and clock circuits stabilize. The display module loads all display supplier’s factory default values to the registers during this
5msec and there cannot be any abnormal visual effect on the display image if factory default and register values are same
when this load is done and when the display module is already Sleep Out –mode. The display module is doing self-diagnostic
functions during this 5msec. It will be necessary to wait 120msec after sending Sleep In command (when in Sleep Out mode)
before Sleep Out command can be sent.
Register
Availability
Status Availability
Normal Mode On, Idle Mode Off, Sleep Out
Yes
Normal Mode On, Idle Mode On, Sleep Out
Yes
Partial Mode On, Idle Mode Off, Sleep Out
Yes
Partial Mode On, Idle Mode On, Sleep Out
Yes
Sleep In Yes
Default
Status Default Value
Power On Sequence
Sleep IN Mode
SW Reset Sleep IN Mode
HW Reset Sleep IN Mode
Flow Chart
It takes 120msec to become Sleep Out mode after SLPOUT command issued.