15.4. Reset Timing
Shorter than 5us
tRW
tRT
ResettingNormal operation
Initial condition
(Default for H/W reset)
RESX
Display Status
Signal Symbol Parameter Min Max Unit
RESX tRW Reset pulse duration 10 uS
5
(note 1,5)
mS
tRT Reset cancel
120
(note 1,6,7)
mS
Note 1: The reset cancel includes also required time for loading ID bytes, VCOM setting and other settings from
NV memory to registers. This loading is done every time when there is HW reset cancel time (tRT)
within 5 ms after a rising edge of RESX.
Note 2: Spike due to an electrostatic discharge on RESX line does not cause irregular system reset according to
the table below: -
RESX Pulse Action
Shorter than 5us Reset Rejected
Longer than 10us Reset
Between 5us and 10us Reset starts
Note 3: During the Resetting period, the display will be blanked (The display is entering blanking sequence,
which maximum time is 120 ms, when Reset Starts in Sleep Out –mode. The display remains the blank
state in Sleep In -mode.) And then return to Default condition for Hardware Reset.
Note 4: Spike Rejection also applies during a valid reset pulse as shown below:
Note 5: When Reset applied during Sleep In Mode.
Note 6: When Reset applied during Sleep Out Mode.
Note 7: It is necessary to wait 5msec after releasing RESX before sending commands. Also Sleep Out