7.1.4. Read Cycle Sequence
The RDX signal is driven from high to low and then allowed to be pulled back to high during the read cycle. The
display module provides information to the host processor during the read cycle while the host processor reads
the display module information on the rising edge of RDX signal. When the D/CX signal is driven to low level,
then input data on the interface is interpreted as command. The D/CX signal also can be pulled high level when
the data on the interface is RAM data or command parameter.
The following figure shows the read cycle for the 8080- MCU interface.
`
Note: RDX is an unsynchronized signal (It can be stopped).
InterfaceHost
ILI9341
Note: Read data is only valid when the D/CX input is pulled high. If D/CX is driven low during read then the
display information outputs will be High-Z.