Data Sheet
a-Si TFT LCD Single Chip Driver
240RGBx320 Resolution and 262K color
ILI9341
The information contained herein is the exclusive property of ILI Technology Corp. and shall not be distributed,
reproduced, or disclosed in whole or in part without prior written permission of ILI Technology Corp.
Page 40 of 233
7.1.11. Data Transfer Break and Recovery
If there is a break in data transmission by RESX pulse, while transferring a command or frame memory data or
multiple parameter command data, before Bit D0 of the byte has been completed, then the driver will reject the
previous bits and have reset the interface such that it will be ready to receive command data again when the
chip select pin (CSX) is activated after RESX have been high state.
S TB
P
D6D7 D5 D4 D2D3D/C D6D7 D5 D4 D2D3 D1 D0D/C
TB
CSX
RESX
SCL
Command /
Parameter / Data
Command
The SCL and SDA during RESX= L is
invalid and next byte becomes command .
Wait for more than 10us
SDA
Driver
(MPU to Driver)
If there is a break in data transmission by CSX pulse, while transferring a command or frame memory data or
multiple parameter command data, before Bit D0 of the byte has been completed, then the driver will reject the
previous bits and have reset the interface such that it will be ready to receive the same byte re-transmitted when
the chip select pin (CSX) is next activated.
S TB P
D6D7 D5 D4D/C D6D7 D5 D4 D2D3 D1 D0D/C
TB
CSX
SDA
SCL
Break
Data / Command / Parameter
Data /
Command /
Parameter
Driver
(MPU to Driver)
If a two or more parameter command is being sent and a break occurs while sending any parameter before the
last one and if the host then sends a new command rather than continue to send the remained parameters that
was interrupted, then the parameters which had been successfully sent are stored and the parameter where the
break occurred is rejected. The interface is ready to receive next byte as shown below.