28 Freescale Semiconductor, Inc.
7.11 Pressure/Altitude Window
7.11.1 P_WND_MSB, P_WND_LSB (0x19, 0x1A)
Pressure/Altitude window value. Unsigned 16-bit value of window value in meters or in 2 Pa units
7.12 Temperature Window
7.12.1 T_WND (0x1B)
Temperature alarm window value. Unsigned 8-bit value °C.
7.13 Minimum Pressure
7.13.1 P_MIN_MSB, P_MIN_CSB, P_MIN_LSB (0x1C, 0x1D, 0x1E)
Register with captured minimum Pressure/Altitude value.
The Altitude data is arranged as 20-bit 2’s complement value in meters. Stored as meters with the 16 bits of P_MIN_MSB and
P_MIN_CSB and with fractions of a meter stored in 4 bits in position 7-4 of P_MIN_LSB.
The Pressure is arranged as 20-bit unsigned data in Pascals. The first 18 bits are located in P_MIN_MSB, P_MIN_CSB and
bits 7-6 of P_MIN_LSB. The 2 bits in position 5-4 of P_MIN_LSB represent the fractional component.
The register is cleared on power-up or manually by writing ‘0’ to the register.
Table 44. P_WND_LSB Register
7 6543210
R
P_W15 P_W 14 P_W 13 P_W 12 P_W 11 P_W 10 P_W 9 P_W 8
W
Reset00000000
Table 45. P_WND_MSB Description
7 6543210
R
P_W7 P_W 6 P_W 5 P_W 4 P_W 3 P_W 2 P_W 1 P_W 0
W
Reset00000000
Table 46. T_WND Register
7 6543210
R
T_W7 T_W6 T_W5 T_W4 T_W3 T_W2 T_W1 T_W0
W
Reset00000000
Table 47. P_MIN_MSB Register
7 6543210
R
P_MIN 19 P_MIN 18 P_MIN 17 P_MIN 16 P_MIN 15 P_MIN 14 P_MIN 13 P_MIN 12
W
Reset00000000
Table 48. P_MIN_CSB Register
7 6543210
R
P_MIN 11 P_MIN 10 P_MIN 9 P_MIN 8 P_MIN 7 P_MIN 6 P_MIN 5 P_MIN 4
W
Reset00000000
Table 49. P_MIN_LSB Register
7 6543210
R
P_MIN 3 P_MIN 2 P_MIN 1 P_MIN0
0000
W
Reset00000000