Datasheet

Datasheet - Apr. 2013 - ams163.5 TSL2591 – 5
All limits are guaranteed. The parameters with min and max
values are guaranteed with production tests or SQC (Statistical
Quality Control) methods.
Figure TSL2591 – 7:
Recommended Operating Conditions
Figure TSL2591 – 8:
Operating Characteristics, V
DD
=3V, T
A
=25ºC (unless otherwise noted)
Symbol Parameter Min Typ Max Units
V
DD
Supply voltage 2.7 3 3.6 V
T
A
Operating free-air temperature -30 70 ºC
Symbol Parameter Conditions Min Typ Max Units
I
DD
Supply Current
Active
Sleep state - no I
2
C activity
275
2.3
325
4
μA
V
OL
INT, SDA output low
voltage
3mA sink current
6mA sink current
0
0
0.4
0.6
V
I
LEAK
Leakage current, SDA,
SCL, INT pins
-5 5 μA
V
IH
SCL, SDA input high
voltage
0.7 V
DD
V
V
IL
SCL, SDA input low
voltage
0.3 V
DD
V
Electrical Characteristics