Datasheet
2016 product data manual of PLANTOWER
Technical Index
Parameter
Index
unit
Range of measurement
0.3~1.0;1.0~2.5;2.5~10
Micrometer(μ m)
Counting Efficiency
50%@0.3μ m 98%@>=0.5μ m
Effective Range(PM2.5
standard)
0~500
μ g/m³
Maximum Range(PM2.5
standard)*
≥1000
μ g/m³
Resolution
1
μ g/m³
Maximum Consistency Error
(PM2.5 standard data)*
±10%@100~500μ g/m³
±10μ g/m³@0~100μ g/m³
Standard Volume
0.1
Litre(L)
Single Response Time
<1
Second(s)
Total Response Time
≤10
Second(s)
DC Power Supply
Typ:5.0 Min:4.5 Max: 5.5
Volt(V)
Active Current
≤100
Milliampere(mA)
Standby Current
≤200
Microampere(μ A)
Interface Level
L <0.8 @3.3 H >2.7@3.3
Volt(V)
Working Temperature Range
-10~+60
℃
Working Humidity Range
0~99%
Storage Temperature Range
-40~+80
℃
MTTF
≥3
Year(Y)
Physical Size
50×38×21
Millimeter(mm)
Note 1: Maximum range means that the highest output value of the PM2.5 standard
data is not less than 1000.
Note 2:“PM2.5 standard data” is the “data2” in the appendix.