Datasheet
2016 product data manual of PLANTOWER
Endurance Characteristics
No
Item
Test Method
Characteristics
n
C
1
Long Running
1. 10 ㎡ closed Lab,,20~25℃,
humidity 30%~70%,particle
generator and air cleaner
2. DC 5V power supply
3. Check consistency after 720
hours’ running
10 samples during
0~500μ g/m³
0~100μ g/m³
Maximum Error≤
±15μ g/m³
100~500μ g/m³
Maximum Error≤
±15%
FAN does not
screeched
n=30
C=0
2
High
Temperature
Operation
1. 10 ㎡ constant temperature Lab
2. 43℃,humidity 70%,
3. particle generator and air
cleaner
4. DC 5V power supply
5. Check consistency
n=10
C=0
3
Cold
Operation
1. 10 ㎡ constant temperature Lab
2. -5℃,humidity 30%,
3. particle generator and air
cleaner
4. DC 5V power supply
5. Check consistency
n=10
C=0
4
Vibration
1. 10 ㎡ closed Lab,,20℃,humidity
50%,particle generator and air
cleaner
2. DC 5V power supply and check
consistency
3. Frequency:50Hz。
4. acceleration:9.8/ S²。
5. Direction:X、Y、Z
6. Vibration Amplitude:±2mm。
7. Time:X、Y、Z –way, Per 1 hour
n=5
C=0
5
High
Temperature
and Humidity
Storage
1. Constant temperature cabinet
2. 70℃,humidity 90%~95,
3. Check consistency after 500
hours’ storage
10 samples during
0~500μ g/m³
0~100μ g/m³
Maximum Error≤
±10μ g/m³
100~500μ g/m³
Maximum Error≤
±10%
n=10
C=0
6
Cold Storage
1. Constant temperature cabinet
2. -30℃,humidity 90%~95,
3. Check consistency after 500
hours’ storage
n=10
C=0
7
Variation of
4. 10 ㎡ closed Lab,,20℃,humidity
n=5










