Datasheet
TSL2560, TSL2561
LIGHT-TO-DIGITAL CONVERTER
TAOS059Q − NOVEMBER 2009
3
The LUMENOLOGY r Company
r
r
Copyright E 2009, TAOS Inc.
www.taosinc.com
Terminal Functions
TERMINAL
NAME
CS, T, FN
PKG
NO.
CL
PKG
NO.
TYPE
DESCRIPTION
ADDR SEL 2 3 I SMBus device select — three-state
GND 3 2 Power supply ground. All voltages are referenced to GND.
INT 5 6 O Level or SMB Alert interrupt — open drain.
SCL 4 4 I SMBus serial clock input terminal — clock signal for SMBus serial data.
SDA 6 5 I/O SMBus serial data I/O terminal — serial data I/O for SMBus.
V
DD
1 1 Supply voltage.
Absolute Maximum Ratings over operating free-air temperature range (unless otherwise noted)
†
Supply voltage, V
DD
(see Note 1) 3.8 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital output voltage range, V
O
−0.5 V to 3.8 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital output current, I
O
−1 mA to 20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−40°C to 85°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ESD tolerance, human body model 2000 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltages are with respect to GND.
Recommended Operating Conditions
MIN NOM MAX UNIT
Supply voltage, V
DD
2.7 3 3.6 V
Operating free-air temperature, T
A
−30 70 °C
SCL, SDA input low voltage, V
IL
−0.5 0.8 V
SCL, SDA input high voltage, V
IH
2.1 3.6 V
Electrical Characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
I
Supply current
Active
0.24 0.6 mA
I
DD
Supply current
Power down
3.2 15 μA
V
INT SDA output low voltage
3 mA sink current 0
0.4 V
V
OL
INT, SDA output low voltage
6 mA sink current 0
0.6 V
I
LEAK
Leakage current −5 5 μA