Product Manual

© Adam Equipment Company 2019
6.4.4 ACCUMULATION/ TOTALISING
The totalising function can be used up to a maximum of 99 times before it must be reset.
The totalising display is limited to seven digits maximum.
When the quantity is shown on the quantity display, Press [M+] Key, and then enters the
totalising function. The quantity display shows “Add XX , XX means the Total Number of
Additions. After 3 seconds, the scale will return to the counting mode.
VIEWING ACCUMULATED DATA
When the weight window shows zero, press [M+] key to show the accumulative data. First,
the scale will show total accumulative data as indicated by t – XX in the weighing window.
Press [M+] again, the scale will show all individual stored values as indicated by Add XX in
the weighing window, followed by the stored amount. Press [M+] to view each stored
value.
When the scale shows one of the stored values, press [PST CE] to delete the selected
stored value.
When the scale shows all accumulated data, press [PST CE], all accumulated data will be
deleted.
In weighing mode, press [PST CE], all accumulated will be deleted.
6.5 SETTING THE PLU DATA
In normal weighing mode, use number keypad to input PLU serial number, then press
[PLU], can get the weights name and unit weight of the corresponding weights. The
display will show the item name once and back to normal weighing mode.
6.5.1 EDIT THE PLU DATA
In normal weighing mode, press and hold [PLU] key for 3s to enter PLU date edit mode.
The weight window shows “set”, user input the PLU number, then press [PLU] (or press
“Ux” key directly), the weight window will show the input PLU number. Now, scale enter
into unit weight edit mode.
If this PLU number is already stored, the weight window will show the stored unit weight. If
it is a new one, the weight window will show the unit weight which get in normal weighing
mode. The user can edit the unit weight by use keypad.