Adam Equipment SHS SERIES (P.N. 7.00.6.6.
1.0 CONTENTS 1.0 CONTENTS.........................................................................................1 2.1 INTRODUCTION ..............................................................................2 2.2 TECHNICAL SPECIFICATIONS.......................................................3 2.3 SAFETY NOTICE .............................................................................4 2.4 KEY AND PANEL DESCRIPTION....................................................5 2.
2.0 INTRODUCTION 2.1 INTRODUCTION The SHS Series is a range of heavy-duty lower capacity crane scales The main features include: • Easy Operation & Rugged construction • 15mm bright red LED display enabling a good viewing angle.
2.2 3 TECHNICAL SPECIFICATIONS Model No. Capacity Division SHS-50 50kg 0.01kg SHS-150 150kg 0.02kg SHS-300 300kg 0.
2.3 SAFETY NOTICE The limit stated below is the Ultimate Overload Limits of the scales. Adam Equipment Co. Ltd. Its directors, owners and affiliated companies and organisations cannot be held liable for any resulting damage or injury sustained as a result of the machines being used in excess of their stated capacities or ultimate overload limits. Model No.
2.4 KEY AND PANEL DESCRIPTION [ON/OFF] 2.5 The power switch is located on the rear housing. Use this key to turn the scale ON and OFF. [ZERO] Press the [ZERO] key to return the reading to zero. [UNIT] Press the [UNIT] key to change the weighing unit being displayed. Kg, Lbs and Newtons are available. [HOLD] Use this key to hold the display. When pressed an LED will light at the top left side of the display and the reading on the display will lock and flash.
3.0 OPERATION 3.1 SAFETY INSTRUCTIONS Read this manual carefully before you operate the SHS Crane Scale. • Unpack the Crane Scale carefully from the packaging. • Attach it to your hoist or equivalent existing equipment securely at the ground level to the support ring in the upright position. Make sure that the equipment to which the scale is attached is in proper condition. The operator should be trained for its safe operation.
3.2 BATTERY OPERATION • The lithium battery will operate continuously for 20 hours before requiring recharging. The scale will alert you that the battery is low on charge when the Indicator LED above the battery symbol lights up. • To charge the battery, unclip the battery cover on the rear of the scale and insert the connector into the socket as marked. Plug the charger into the mains power supply and wait until the LED on the charger shows green. The battery is now fully charged.
3.3 BASIC OPERATIONS Power on and off Press the [ON/OFF] button to turn the scale on or off. The display on the scale will show the model capacity then countdown from 9 to 0 before displaying ZERO weight. Zero the scale Press the [Zero] key so that the display shows zero. Hold When the reading may not be perfectly stable or you cannot view a reading easily you can press the [HOLD] key to lock it.
3.4 REMOTE CONTROL UNIT The remote control works via infra red and can be used to operate the SHS from long distances. It operates using 2 x AAA batteries and these can be exchanged by unclipping a cover on the rear of the remote control unit. 3.5 USER PARAMETERS Three USER settable parameters are available on the SHS, to access these power up the scale and whilst the display is counting down press and then release the [UNIT] button. The display should show Bee 0 which is the first of the parameters.
4.0 CALIBRATION • Press the [ZERO] key and power up the scale using the on/off button. • Release the [ZERO] key and the display will show “SPAN”. Make sure the hook is empty unless you intend to use any chains, slings etc to hold the calibration mass. Add any items such as these to the hook before continuing. • Press the [ZERO] button and the display will show “SET” then “00000” when the reading at zero is stable.
5.0 PARTS LIST SHS Part number 11 Description Item No 7.00.1.0.0286 SHS SUPPORT RING 1 7.00.4.0.0091 SHS ON/OFF PUSHBUTTON 2 7.00.4.0.0092 SHS LITHIUM BATTERY PACK - 2 PIECES 3 7.00.4.0.0095 SHS POWER CONNECTOR SOCKET 4 7.00.4.0.0011 SHS COMPLETE HOUSING 7.00.4.0.0093 SHS MAIN PCB 7.00.1.0.0280 SHS LOAD CELL - 50kg 10 7.00.1.0.0281 SHS LOAD CELL - 150kg 10 7.00.1.0.0282 SHS LOAD CELL - 300kg 10 7.00.5.6.0048 SHS KEYPAD PANEL 11 7.00.1.0.0283 SHS HOOK 12 7.00.5.6.
12 © Adam Equipment Company 2012
WARRANTY INFORMATION Adam Equipment offers Limited Warranty (Parts and Labour) for the components failed due to defects in materials or workmanship. Warranty starts from the date of delivery. During the warranty period, should any repairs be necessary, the purchaser must inform its supplier or Adam Equipment Company. The company or its authorised Technician reserves the right to repair or replace the components at any of its workshops depending on the severity of the problems.
Manufacturer’s Declaration of Conformity This product has been manufactured in accordance with the harmonised European standards, following the provisions of the below stated directives: Electro Magnetic Compatibility Directive 2004/108/EC Low Voltage Directive 2006/95/EC Adam Equipment Co. Ltd. Bond Avenue, Denbigh East Milton Keynes, MK1 1SW United Kingdom FCC COMPLIANCE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
ADAM EQUIPMENT is an ISO 9001:2008 certified global company with more than 35 years experience in the production and sale of electronic weighing equipment. Adam products are predominantly designed for the Laboratory, Educational, Health and Fitness, retail and Industrial Segments.