Product Manual
© Adam Equipment 2016 11
Overload Warning-: please do not add any item that exceeds the maximum capacity
of the scale. When the buzzer is sounded and the display shows”-----”, remove the
item to avoid damage to the load cell and scale.
3.5
REMOTE
CONTROLLER
A: Determine increments in which the weight display
B: Hold the settled values
C: Zero the scale
D: Backlight (only used on scales with LCD display)
4.0
CALIBRATION
• Hold [Zero] when the scale is powered on.
• The display on the scale will show “SPAN”. Make sure the hook is
empty or has the slings or chains to be used in place. See Below.
• Depress the [Zero] button, the display on the scale will show “Set” then
“0” and then“0000.0” after few seconds. Zero calibration is now
complete.
• Enter the weight to calibrate with by using [Hold] key to increment a
digit then the [Change/lb/kg] key to move it across the screen left.
• For example, the display on the IHS will display “3000.0” for a 3 ton
calibration mass.
• Add the calibrated mass on the hook, it the best that the mass is close
to the capacity where possible.
• When the scale is stable, press the [Zero]. The display shows ‘HOLd’.
• After a few seconds, the calibration is complete.