Installation guide
3-11
Installing the Driver
7 Once the system has started, verify that an entry has been made 
for the new controller in the modules configuration file by 
typing:
cat\etc\modules.conf
Look for an entry similar to:
alias scsi_hostadapter dpt_i20
If the appropriate entry is not present, use an editor such as 
VI to make the change.
8 For the new module to start when the system boots, a new 
ramdisk will be required. An alternative to creating a new 
ramdisk is to allow the Adaptec RAID module to be started 
each time the system is booted by using the following 
command:
modprobe dpt_i20
9 To create a new ramdisk, change to the \boot directory. Rename 
the existing ramdisk to something similar to:
mv initrd-2.4.18-3.img initrd-2.4.18-3.img.old
Note: This assumes you are using kernel 2.4.18-3. If your 
kernel version is different, please use the appropriate 
kernel number. Consult your system documentation for 
help on creating the initrd if needed.
10 To create a new ramdisk, type the following from the \boot 
directory:
mkinitrd initrd-2.4.18-3.img
11 Restart the server to verify that the module will now load on 
booting the system. When the system has booted, type lsmod 
and look for the entry for the dpt_i20 module.
12 Finally; partition, format, and create mount points for the 
attached RAID arraysor hard drives that will be used with the 
system.
R2N2 RAID IG.BOOK Page 11 Monday, September 9, 2002 12:01 PM