9 To add a drive to a secondary controller, type 
diskadd cCCbBBtTTdDD
For example, a new drive or array is connected to a secondary 
Adaptec RAID controller on Channel A and the drive has a 
TID 0. The controller number is 1 because it is a secondary 
controller. Therefore, the command would be 
diskadd c1b0t0d0
For details on 
diskadd, refer to the diskadd(1M) man page.
FreeBSD
The Adaptec RAID controller driver is embedded in the kernel for 
versions 4.1.1 and later. Therefore, you do not need to do anything 
related to driver installation once your operating system is installed.
For the most up-to-date information on Adaptec’s support of 
FreeBSD, or to download driver sources, visit 
http://opensource.adaptec.com.
Caution: When adding a Zero Channel RAID (ZCR) 
controller to an existing system, backup all data from 
system drives prior to the installation. If the boot device is 
connected to one of the onboard SCSI channels, the 
operating system will need to be reinstalled after installing 
the ZCR controller.
!