Installation guide
Table Of Contents
- Command Line Interface
- Reference Guide
- Introduction
 - General Control Commands
 - container Commands
- container add_level
 - container create mirror
 - container create mmirror
 - container create mstripe
 - container create mvolume
 - container create raid5
 - container create stripe
 - container create volume
 - container delete
 - container extend file_system
 - container extend mvolume
 - container extend volume
 - container list
 - container lock
 - container move
 - container promote
 - container readonly
 - container readwrite
 - container reconfigure
 - container release_cache
 - container remove drive_letter
 - container remove failover
 - container remove file_system
 - container remove global_failover
 - container restore RAID5
 - container scrub
 - container set cache
 - container set failover
 - container set global_failover
 - container set io_delay
 - container set label
 - container show cache
 - container show failover
 - container split
 - container unlock
 - container unmirror
 
 - controller Commands
- controller details
 - controller firmware compare
 - controller firmware save
 - controller firmware update
 - controller list
 - controller pause_io
 - controller rescan
 - controller reset_scsi_channel
 - controller resume_io
 - controller set automatic_failover
 - controller set array_verify
 - controller show automatic_failover
 - controller show channels
 - controller show array_verify
 
 - disk Commands
 - diagnostic Commands
- diagnostic clear boot_parameters
 - diagnostic dump structures
 - diagnostic dump text
 - diagnostic load_arrays
 - diagnostic moderation set count
 - diagnostic moderation set timer
 - diagnostic moderation show count
 - diagnostic moderation show timer
 - diagnostic set boot_parameter
 - diagnostic show boot_parameter
 - diagnostic show history
 
 - logfile Commands
 - task Commands
 - enclosure Commands
- enclosure activate slot
 - enclosure identify slot
 - enclosure list
 - enclosure prepare slot
 - enclosure set alarm
 - enclosure set door
 - enclosure set fan
 - enclosure set interval
 - enclosure set power
 - enclosure set scsiid
 - enclosure set temperature
 - enclosure show fan
 - enclosure show power
 - enclosure show slot
 - enclosure show status
 - enclosure show temperature
 
 - Automated Scripts
 
 
 - Reference Guide
 

3-70
container Commands
container reconfigure
To change the configuration of an array, use the container 
reconfigure
 command. The container reconfigure 
command allows you to perform the following operations:
■ Transform an array from one type to another type
You can transform an array from one type to another type. 
For example, you can transform a RAID 1 to a RAID 5 array. 
You specify the appropriate switches that the container 
reconfigure
 command provides to transform an array.
■ Add more SCSI drives to an array
You can add more SCSI drives to an array by specifying one 
or more SCSI devices. This action extends the array. The 
command uses the freespace(s) from the SCSI device(s) you 
specify to reconfigure the array.
For example, you can extend a RAID  array by specifying one 
or more devices. In this case, the array grows, but remains a 
RAID 1.
■ Change an array’s stripe size
You can change an array’s stripe size by specifying the 
appropriate switch with a valid stripe size. For example, you 
can change the stripe size of a stripe set from 16K to 32K.
Note: The stripe size for a RAID 50 array is always 
64 KB.
■ Change an array’s partition size
You can change an array’s partition size by specifying the 
appropriate switch with a valid partition size. For example, 
you can change the partition size of a mirror set from 500 MB 
to 800 MB.
■ Extend an existing file system
You can extend an existing file system by specifying the 
appropriate switch. (The command extends the file system 
after completing the reconfigure operation.)