Installation guide
Table Of Contents
- Command Line Interface
- Reference Guide
- Introduction
- General Control Commands
- container Commands
- container add_level
- container create mirror
- container create mmirror
- container create mstripe
- container create mvolume
- container create raid5
- container create stripe
- container create volume
- container delete
- container extend file_system
- container extend mvolume
- container extend volume
- container list
- container lock
- container move
- container promote
- container readonly
- container readwrite
- container reconfigure
- container release_cache
- container remove drive_letter
- container remove failover
- container remove file_system
- container remove global_failover
- container restore RAID5
- container scrub
- container set cache
- container set failover
- container set global_failover
- container set io_delay
- container set label
- container show cache
- container show failover
- container split
- container unlock
- container unmirror
- controller Commands
- controller details
- controller firmware compare
- controller firmware save
- controller firmware update
- controller list
- controller pause_io
- controller rescan
- controller reset_scsi_channel
- controller resume_io
- controller set automatic_failover
- controller set array_verify
- controller show automatic_failover
- controller show channels
- controller show array_verify
- disk Commands
- diagnostic Commands
- diagnostic clear boot_parameters
- diagnostic dump structures
- diagnostic dump text
- diagnostic load_arrays
- diagnostic moderation set count
- diagnostic moderation set timer
- diagnostic moderation show count
- diagnostic moderation show timer
- diagnostic set boot_parameter
- diagnostic show boot_parameter
- diagnostic show history
- logfile Commands
- task Commands
- enclosure Commands
- enclosure activate slot
- enclosure identify slot
- enclosure list
- enclosure prepare slot
- enclosure set alarm
- enclosure set door
- enclosure set fan
- enclosure set interval
- enclosure set power
- enclosure set scsiid
- enclosure set temperature
- enclosure show fan
- enclosure show power
- enclosure show slot
- enclosure show status
- enclosure show temperature
- Automated Scripts
- Reference Guide

3-74
container Commands
/raid5{=boolean}
Specifies whether to reconfigure the existing array into a
RAID 5 array. If you specify TRUE, the command reconfigures
the existing array into a RAID 5 array. If you specify FALSE,
the command does not reconfigure the existing array into a
RAID 5 array.
This switch defaults to FALSE.
/raid10{=boolean}
Specifies whether to reconfigure the existing array into a
RAID 10 array. If you specify TRUE, the command
reconfigures the existing array into a RAID 10 array. If you
specify FALSE, the command does not reconfigure the
existing array into a RAID 10 array.
This switch defaults to FALSE.
/stripe{=boolean}
Specifies whether to reconfigure the existing array into a stripe
set. If you specify
TRUE
, the command reconfigures the existing
array into a stripe set. If you specify
FALSE
, the command does
not reconfigure the existing array into a stripe set.
This switch defaults to FALSE.
/volume{=boolean}
Specifies whether to reconfigure the existing array into a
volume set. If you specify TRUE, the command reconfigures
the existing array into a volume set. If you specify FALSE, the
command does not reconfigure the existing array into a
volume set.
This switch defaults to FALSE.
/wait{=boolean}
Specifies whether the command performs the array
reconfiguration operation synchronously or asynchronously.
If you set this switch to TRUE, the command performs the
array reconfiguration operation synchronously, which means
the command prompt does not return until the array
reconfiguration operation completes. If you set this switch to
FALSE, the command performs the array reconfiguration
operation asynchronously, which means the command
prompt returns immediately.